Specifications and Reference Data
May 2019
Table A-8. Air Flow Rate Limits at 59 °F (15 °C)–Line Sizes 3- through 4-in.
Process
Flow Rate
Pressure
Limits
0 psig
(0 bar G)
50 psig
(3,45 bar G)
100 psig
(6,89 bar G)
150 psig
(10,3 bar G)
200 psig
(13,8 bar G)
300 psig
(20,7 bar G)
400 psig
(27,6 bar G)
500 psig
(34,5 bar G)
Table A-9. Air Flow Rate Limits at 59 °F (15 °C)–Line Sizes 6- through 8-in.
Process
Flow Rate
Pressure
Limits
0 psig
(0 bar G)
50 psig
(3,45 bar G)
100 psig
(6,89 bar G)
150 psig
(10,3 bar G)
200 psig
(13,8 bar G)
300 psig
(20,7 bar G)
400 psig
(27,6 bar G)
500 psig
(34,5 bar G)
92
Minimum and Maximum Air Flow Rates
for line sizes 3-in./DN 80 through 4-in./DN 100
3-in./DN 80
Rosemount 8600D
ACFM
max
770
min
66.8
max
770
min
31.8
max
770
min
23.9
max
770
min
20.0
max
770
min
20.0
max
718
min
20.0
max
625
min
20.0
max
560
min
20.0
Minimum and Maximum Air Flow Rates
for line sizes 6-in./DN 150 through 8-in./DN 200
6-in./DN 150
Rosemount 8600D
ACFM
max
3009
min
261
max
3009
min
124
max
3009
min
93.3
max
3009
min
78.2
max
3009
min
78.2
max
2807
min
78.2
max
2442
min
78.2
max
2188
min
78.2
4-in./DN 100
Rosemount 8600D
ACMH
ACFM
1308
1326
114
115
1308
1326
54.1
54.8
1308
1326
40.6
41.1
1308
1326
34.0
34.5
1308
1326
34.0
34.5
1220
1237
34.0
34.5
1062
1076
34.0
34.5
951
964
34.0
34.5
8-in./DN 200
Rosemount 8600D
ACMH
ACFM
5112
5211
443
452
5112
5211
211
215
5112
5211
159
162
5112
5211
133
135
5112
5211
133
135
4769
4862
133
135
4149
4228
133
136
3717
3789
133
136
Reference Manual
00809-0100-4860, Rev BF
ACMH
2253
195
2253
93.2
2253
69.8
2253
58.6
2253
58.6
2102
58.6
1828
58.6
1638
58.6
ACMH
8853
768
8853
365
8853
276
8853
229
8853
229
8260
229
7183
229
6437
229
Rosemount 8600 Vortex Flow Meter