Troubleshooting Flow Diagrams
Engage™ and Inspire™ Consoles
TELEMETRy HR NOT wORKING
STArT
replace AZ-
MIB wiring S/B
AK65-00043-
0001 rev A2
or later.
Verify / fix
grounding
through frame
and at console.
No
Correct Hr?
No
Yes
Done.
No
Correct Hr?
No
Yes
Done.
Check
manager's
enabled in Manager's
settings in
diagnostics.
Yes
Produce Hr
signal with
Polar Simulator.
Replace
telemetry
receiver.
No
Replace cable
between
receiver and
console.
Replace MIB.
No
Reposition
telemetry
receiver.
Telemetry Hr
No
settings?
Correct Hr shown
Yes
on Hr test page?
Correct Hr shown
Yes
on Hr test page?
Correct Hr shown
Yes
on Hr test page?
Correct Hr shown
Yes
on Hr test page?
Correct Hr shown
No
on Hr test page?
Yes
Finished.
CN 26
M051-00K70-B111
Change
settings
to enable
telemetry Hr.
Finished.
Finished.
Finished.
Finished.
Unexpected
error, contact
LF.