Error Message Tables
Engage™ and Inspire™ Consoles
MESSAGE
"Notify maintenance
communication
timeout (motor
controller)."
2
"Notify maintenance
motor controller error
(thermal shutdown)."
"Notify maintenance
motor temperature
trip."
"Warning - step
off belt, maximum
voltage trip."
"Notify maintenance
motor controller error
(hardware current
trip)."
DESCRIPTION
Lost communications
with the motor
controller (i.e. module
communication
timeout).
Motor controller
shut down due
to excessive
temperature.
Motor shut down
due to excessive
temperature.
Excessive belt motor
bus voltage detected.
Excessive motor
current detected.
POSSIBLE CAUSE
Broken
communication lines,
JW3 installed on
DSP M/C.
M/C compartment
airflow restricted, hot
air is being blown on
it, located in direct
sunlight.
Excessively worn
belt/deck.
Faulty/intermittent
thermal switch in
motor.
M/C compartment
airflow restricted, hot
air is being blown on
it, located in direct
sunlight.
Excessively worn
belt/deck.
User is driving the
belt with sufficient
energy to raise the
bus voltage, most
likely at high inclines.
Input line has voltage
surge problems.
Excessive motor
current caused
by a failed motor,
intermittent motor or
motor connection(s).
A possible but
unlikely cause would
be a severely worn
belt/deck.
REMEDy
remove JW3.
Check/replace cabling down to the M/C.
Vibration is causing intermittent operation
from loose connection.
Clean the M/C compartment, insure adequate
ventilation is available and it is not being
heated by a heating register, move from direct
sunlight. replace belt/deck if power level is
excessive.
Check motor thermal switch connections.
Check clean the M/C compartment, insure
adequate ventilation is available and it is not
being heated by a heating register, move from
direct sunlight. replace belt/deck if power
level is excessive. replace motor if error
keeps occurring after the motor has cooled
down and no other solution has worked.
Instruct the user to not drive the belt at high
inclines or use a lower incline.
Contact an electrician to diagnose/correct a
power line problem.
Verify that all motor connections and cables
are solid. If start-up power is very weak a
phase may be faulty. Perform a phase test to
verify the system or diagnose a problem.
CN 15
M051-00K70-B111
18