Problem Symptom Tables
Engage™ and Inspire™ Consoles
SyMPTOM
No power to console.
No audio; screen does not
turn on.
No backlight;
screen is dark.
Touch Screen is not
accurate.
Touch Screen does not
respond.
Snow and noise appear on
screen.
Unable to receive cable
channels.
Channels do not change.
POSSIBLE CAUSE
No power to base.
Faulty main cable or bad
cable connection.
Faulty main cable.
Defective SBC.
Defective LCD screen.
Arcing between low voltage
input wires and inverter's
high voltage output.
Defective inverter.
Defective SBC.
Defective backlights.
Touch Screen needs
calibration.
Defective LCD Touch
Screen.
Defective LCD Touch
Screen.
Gasket pressing on touch
screen's active area.
Air / cable setting incorrect.
Defective coax – no signal.
Defective tuner board.
Air / cable setting incorrect.
Defective coax – no signal
defective.
Touch Screen needs
calibration.
Defective Touch Screen.
Defective SBC.
Defective analog tuner.
REMEDy
Check that there is power at the outlet, breaker and
switch all OK.
Check +12VDC at Pins 11 and 12 of main cable that goes
to MIB. replace cable if necessary.
Check for power to console.
replace SBC.
replace LCD panel.
route Inverter input wires under the iPod Authentication
pcb (92349).
Test inverter – replace if necessary.
replace SBC.
replace LCD panel.
Calibrate Touch Screen.
replace the Touch Screen.
replace the Touch Screen.
Loosen bezel/touchscreen and push gasket away from
touch screen.
Change setup to proper setting.
Verify signal present.
Replace tuner board.
Change setup to proper setting.
Verify signal present.
Calibrate Touch Screen.
replace Touch Screen.
replace SBC.
Replace tuner.
CN 10
M051-00K70-B111
13

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Engage elevation seriesInspire elevation series