Error Message Tables
Engage™ and Inspire™ Consoles
MESSAGE
"Module
communication error.
retroFit DSP MC
detected."
"Edit base assembly
serial #."
"Maintenance" shown
at the top of the
screen.
"Please pedal."
2
DESCRIPTION
SBC has detected
that a "retroFit"
DSP motor controller
has been installed.
retroFit controllers
are not to be used on
Elevation products.
This is a prompt to
enter the base serial
number and the
product type.
This is a data entry
prompt that will ask
the tech to select
either "replacing
Console" or
"replacing Motor
Controller".
Initialization does not
finish (stuck in this
mode) due to lack
of communication
between MIB & motor
controller.
POSSIBLE CAUSE
SBC has detected
that an invalid DSP
motor controller has
been installed.
The prompt will
occur if there is no
valid configuration
data in both the
SBC registry and
the motor controller.
This will also occur if
both the console and
motor controller are
replaced at the same
time.
This prompt
occurs if the basic
configuration data
stored in both the
registry and motor
controller doesn't
match. This will
occur if the console
or motor controller
is replaced with
assemblies that
already have
configuration data
stored in them
(These assemblies
are typically sent
out with blank basic
configuration data
in which case you
wouldn't see this
prompt).
Most likely: JW3
installed on DSP
M/C.
Less likely: Broken
rx/Tx lines in cable,
MIB or M/C.
SECTION
replace the M/C with one with the correct
assembly number.
Enter the base serial number located on
the label attached to the frame and set the
correct product type when prompted.
If you replaced the console, then select
"replacing Console". Otherwise select
"replacing Motor Controller".
remove JW3. Check/replace cabling down to
the M/C.
CN 14
M051-00K70-B111