IE340 Series Installation Guide
Power
Requirements
50
Caution
The output power of the IE048-480 power supply is affected by the
input voltage and ambient temperature. Refer to the data sheet for
the derating curve.
The IE048-480 power supply is sold separately.
The IE340 switches have the following power supply requirements:
The DC input voltage for the IE340-12GP, IE340-12GT, and
IE340-20GP switches has to be between 18 and 57Vdc; this range
is absolute with no tolerance.
The DC input voltage for the IE340L-18GP switch has to be
between 46 and 57Vdc; this range is absolute with no tolerance.
DC input voltage has to meet the requirements in Table 9 on
page 51 to enable PoE sourcing.
DC input voltage must not exceed 57Vdc to avoid the device
breakdown.
DC input current has to be available continuously over the
operating temperature range and required consumption.
Note
The IE340 switches can be powered by one or two power supplies.
A single power supply that meets the above requirements can fully
power the switches. Adding a second power supply adds power
redundancy.
IE340 PoE PSE switches can operate in the following modes:
Non-PoE mode: All network devices connected to the switch do
not require PoE sourcing.
PoE mode: Some or all network devices connected to the switch
require PoE sourcing, in accordance with std. IEEE 802.3at Type 1
"PoE."
PoE+ mode. Some or all network devices connected to the switch
require PoE sourcing, in accordance with std. IEEE 802.3at Type 1
and or Type 2 "PoE+."
Table 9 on page 51 describes the input voltage requirements; the listed
voltage ranges are absolute with no tolerance.