98
Input Supply Voltages:
AT-PWR10 (AC) Power Supply: 100 - 240V AC, 3A maximum, 50/60 Hz
AT-PWR11 (DC) Power Supply: 40 - 60V DC, 7.2A maximum
RFI Emission
AT-8400 Series Chassis:
AT-8400 Line Cards:
Immunity:
Electrical Safety:
Laser:
The following specifications apply to all AT-8400 line cards -- the
AT-8411, AT-8412, AT-8413, and AT-8414 -- unless specifically noted:
Maximum Operating
Temperature:
Maximum Storage
Temperature
AT-8411, AT-8412, AT-8413: -20° C to 80° C (-4° F to 176° F)
AT-8414:
Operating and Storage
Altitude:
Relative Humidity
AT-8411, AT-8412, AT-8413: 5% to 80% maximum (non-condensing)
AT-8414:
FCC Class A, EN55022 Class A, EN61000-3-2,
EN61000-3-3, VCCI Class A, C-TICK
FCC Class A, EN55022 Class A,VCCI Class A,
C-TICK
EN55024
EN60950 (TUV), UL60950 (UL/cUL)
EN60825
0° C to 40° C (32° F to 104° F)
-25° C to 75° C (-13° F to 167° F)
Up to 3,048 meters (10,000 feet)
5% to 95% maximum (non-condensing)