Installation Instructions - Gabarron Elnur ECOMBI HHR Series Installation Instructions Manual

High heat retention, ecodesign lot20 compliant
Table of Contents

Advertisement

INSTALLATION INSTRUCTIONS

The symbols used in the text are explained below:
WARNING
This indication shows the possibility of causing death from electric shock.
WARNING
This indication shows the possibility of causing death or serious injury.
!
CAUTION
This indication shows the possibility of causing injury or damage to
!
properties only.
Symbol for useful information.
!
• The warranty of the heater will not cover any
damage caused by non-observance of any of
these instructions.
• The installation must be carried out in accordance
with the current IEE regulations. Any installation
or reinstallation has to be carried out by a skilled
or instructed person.
• Please check that cable, isolation switch gear and
power supply is sufficient for the voltage and watts
shown on the rating label.
• This appliance must be Earthed.
• This appliance should not be installed just below
an electrical socket.
• This appliance must be installed outside of zone 2,
the controls should not be accessible by anyone
using a bath or shower.
• If during any installation the thermal insulation shows
any sign of damage, it must be replaced.
IMPORTANT: Wiring procedures and connections should be in accordance to current IEE
!
regulations.
Elnur powered by Gabarrón | ECOMBI HHR | Installation Guide
Keep combustible materials, such as furniture, pillows,
bedding, papers, clothes and curtains at least a foot
(300mm) from the front, sides and rear of the heater.
It is essential that the indicated minimum clearances
are maintained.
Note: Items such as shelves that are mounted above
the heater below the minimum 250mm clearance will
affect the performance of the heater.
• This heater should be switched off at the isolation
switch and/or circuit breaker before any repair work
is carried out on the heater.
• This appliance is only intended for a fixed installation
with a permanent connection and is not for portable
use. After the installation a survey of the first charge
cycle should be carried out to ensure that the main
input thermostat switches off. Ventilate the room
during this first cycle.
• Never open a charged heater; temperatures can rise
above 600°C.
• To maintain stability, it is essential that the heater
is placed on a level surface and care should be taken
to avoid irregular surfaces, such as may result from
carpets or tiled surrounds partially protruding under
the heater.
• The presence of air particles of smoke, dust, scented
candles and other pollutants, could in time, discolour
the walls and surfaces around the heater
3