  • Page 1 INSTALLATION INSTRUCTIONS AND USER GUIDE ECOMBI SSH SMART STORAGE HEATER ECOSSH158 ECOSSH208 ECOSSH308 ECOSSH408 Please, read these instructions CAREFULLY before installing or using this appliance for the first time.
  • Page 2 1. –IMPORTANT INFORMATION When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following: • WARNING: Please read all instructions before installing or using this heater for the first time. •...
  • Page 3: Installation Instructions

    2. - INSTALLATION INSTRUCTIONS The symbols used in the text are explained below: WARNING This indication shows the possibility of causing death from electric shock. WARNING This indication shows the possibility of causing death or serious injury. CAUTION This indication shows the possibility of causing injury or damage to properties only. Symbol for useful information.
  • Page 4 Turn the carton upside down to allow the heater to stand on its feet and remove the carton. Check that it is the correct model and that it is in good conditions. Check that all parts have been delivered and are intact. 1 Ecombi SSH heater casing.
  • Page 5 7. - Disconnect the aluminum heating element by removing the FAST-ON terminal on each end of the element. WARNING Steel edges can cut. Next unscrew the inner panel and remove it. CAUTION In the interior part of this inner panel there is a very delicate thermal insulation MICROTHERM panel.
  • Page 6 8. Do not disconnect the electrical heating elements. Remove the packing cardboard. Lift and tilt the elements outwards being careful not to damage the insulation on the bottom of the heater. 9. - Place the storage bricks carefully, with the flat side facing the back of the heater. Arrange two row levels of bricks. 10.
  • Page 7 11. Replace the inner front panel. If the bricks have been fitted correctly you will have no difficulty in replacing the panel. Make sure the bottom edge of the inner panel is inside the front lip of the heater. Please see below: RIGHT WRONG POSITION...
  • Page 8: Connection / Disconnection

    3. - OPERATING INSTRUCTIONS CAUTION: DO NOT USE THIS HEATER TO DRY CLOTHES. Do not cover this heater at any time. CONNECTION / DISCONNECTION Power switch.All models are equipped with a switch on the back side panel. It is used to connect and disconnect ECOMBI SSH. KEYBOARD: G-Control Hub Open Windows Detection...
  • Page 9: Operation Modes Selection

    OPERATION MODES SELECTION Press , the operation modes are displayed, with the selected one flashing. to select the desired operation mode. Confirm with The heater has three different operation modes: Auto, Manual override and Standby Mode. Auto: The setpoint temperature varies according to the weekly schedule setup in the unit.
  • Page 10: Time Setting

    AUTO MODE – Programming & Time Setting Programming PROGRAMMING Enter programming: Press & Hold until the following is shown. The first segment will start to flash. By pressing you can select whether you want a Frost Protection setting (3°C), Moon setting (18°C) or Comfort Select temperature level: setting...
  • Page 11 MANUAL OVERRIDE Increase temperature set point In manual mode, the heater will maintain the temperature set point and will ignore the pre-set program. SSH will maintain the selected temperature for the 24 hours of the day. Use this mode, when the same temperature is desired for every hour in the week.
  • Page 12 Access to the parameter to move on through the different parameters. to access the parameter you want to modify. Change the value using the navigation keys . Confirm the new value with It is possible to save the changes and exit at any moment by pressing SSH general parameters that can be modified by the user are detailed below: - UP01: Initial % of storage charge.
  • Page 13 SMART STORAGE HEATER: SSH optimizes the energy management and consumption and provides the heat demand requested by the user in each period of time reaching the desired comfort. Smart charging control SSH allows optimizing the energy management and consumption using a linear regression model based on the temperature registered in the core of SSH to determine the current % of the storage heater charge and use this information to charge only the heat necessary to supply the daily heat demand and avoid unnecessary energy consumption.
  • Page 14 DEFAULT SETTINGS & RESET To reset the unit to factory default settings, press simultaneously for 5 seconds until the message SrES is displayed. Confirm the reset with Default Values 21ºC Sun: Comfort temperature 18ºC Moon: Economic temperature 3ºC Frost protection temperature UP01: Initial % of storage charge UP02: Starting time off peak period 1 00:00...
  • Page 15: Troubleshooting

    4.- REMOTE OPERATION USING THE WIFI G-CONTROL HUB It is possible to control the full operation of the unit remotely with Gabarron-Elnur app or app-web. The unit must be connected to a Wifi G-Control Hub connected to the internet to use this feature.
  • Page 16: Cleaning Maintenance Instructions

    Once its useful life is finished please take the device to a recycling depot so that its components can be recycled in an appropriate way. 7.- MAIN COMPONENTS LIST Storage Heating Element (All except ECOSSH158) Ref. 15190091 Switch Ref. 46100530 Storage Heating Element (ECOSSHI58) Ref.
  • Page 17 EMITTER LIMITER CUT OUT MANUALLY LIMITER EMITTER LIMITER CUT OUT MANUALLY LIMITER...
  • Page 18 EMITTER LIMITER CUT OUT MANUALLY LIMITER 9.- THECNICHAL FEATURES Modelo ECOSSH158 ECOSSH208 ECOSSH308 ECOSSH408 CONNECTION 230 - 240V ~ 230 - 240V ~ 230 - 240V ~ 230 - 240V ~ CONVECTOR OUTPUT* 230/240 450/490W 600/653W 900/980W 1200/1307W STORAGE HEATER OUTPUT 230/240...
  • Page 19: Product Fiche

    PRODUCT FICHE MODEL(S): GABARRON ECOSSH158, ECOSSH208, ECOSSH308, ECOSSH408 Value Item Symbol Unit ECOSSH ECOSSH ECOSSH ECOSSH Heat Output Nominal heat output 1062 1415 2123 2831 Minimum heat output N.A. N.A. N.A. N.A. Maximum continuous 1062 1415 2123 2831 max,c heat output...
  • Page 20 The symbol on the product or in its packaging indicates that this product may not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product.