Do you have a question about the ECOHHR20 and is the answer not in the manual?
Questions and answers
GRAHAM JOHN PEARSON
February 3, 2025
Hi
Can the unrestricted supply be via a socket,switched spur or fused outlet?
1 comments:
Mr. Anderson
February 10, 2025
No, the Gabarron ECOHHR20 storage heater requires two electrical supplies: an economy tariff supply (off-peak or restricted) and a 24-hour supply (on-peak or unrestricted). The economy supply must be connected via a 20A double pole isolator switch, while the 24-hour supply must be connected via a fused double pole isolator switch or a fused RCD isolator switch. Therefore, it cannot be supplied via a standard socket, switched spur, or fused outlet.
Page 1
ADVANCED INSTALLATION INSTRUCTIONS ECOMBI HHR SMART STORAGE HEATER ECOHHR20 ECOHHR30 ECOHHR40 Please, read these instructions CAREFULLY before installing or using this appliance for the first time.
Page 2
1. –IMPORTANT INFORMATION When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following: • WARNING: Please read all instructions before installing or using this heater for the first time. •...
2. - INSTALLATION INSTRUCTIONS The symbols used in the text are explained below: WARNING This indication shows the possibility of causing death from electric shock. WARNING This indication shows the possibility of causing death or serious injury. CAUTION This indication shows the possibility of causing injury or damage to properties only. Symbol for useful information.
Page 4
3.- Screw on the wall the superior fixing fitting, making the two required drills at the recommended distance depending on the model. Use the dowels and screws contained in the plastic bag to fix the fitting to the wall. 4.
Page 5
6. - Connect the heater using the wiring diagram included at the end of this manual. Tighten properly the connection block screws. Use only silicone insulated cables. Do not leave any remaining wire inside the heater. WARNING Touching live connections can cause serious personal injury. 7.
Page 6
9. - Place the heating elements back into their original position. Place the second row of storage bricks with the flat side facing out and always on the heating elements supporting tabs. Next replace the metallic plate in the top of the storage core, between the bricks and the Microthermal insulation panel with the flat side facing up.
Page 7
RELOCATION WARNING: Relocation to another location must be carried out by an experienced technician. If during reinstallation the thermal insulation shows any sign of damage, it must be removed and replaced by an identical part. MANUALLY RESET TEMPERATURE LIMITER This heater employs a manually reset temperature limiter (see CUT OUT in the connection diagram). This safety device operates when high temperatures are reached at the top of the heater.
3. - OPERATING INSTRUCTIONS CAUTION: DO NOT USE THIS HEATER TO DRY CLOTHES. Do not cover this heater at any time. 3.1. CONNECTION / DISCONNECTION Power switch.All models are equipped with a switch on the back side panel. It is used to connect and disconnect HHR. 3.2.
3.5. OPERATION MODE: The HHR operates in weekly programming mode. The temperature level (ECO, Frost protection and Comfort) can be set for each period of time (30’ minutes) in the different days in the week. Storage heater resistances will operate during off peak rate in order to charge the heater according to the demand of the room. A fan is used to discharge the heating core if necessary to reach the current set point temperature.
Page 10
Set point temperature level forced function It is possible to change temporarily the temperature level for the current time interval. The modification in the temperature level will be maintained until the next changed in programming temperature level. To change temporarily the current temperature level: Hold key for 4 seconds to activate temporarily the Economic temperature in the current temperature level.
Open Window Detection With open window detection activated, the fan assisted discharge and the balance resistance working will be disconnected automatically when a sharp decrease in temperature in the room is detected avoiding energy wastage. After this period of time, the storage heater returns to the prior operation mode.
3.9.DEFAULT SETTINGS: By pushing the clock key at the same time as we turn on the heater with the power switch, located at the right-side panel, software resets to the default settings. Four horizontal blinking segments will appear in the screen to confirm it. The default programming, all time intervals in frost protection temperature level are set.
Page 16
WARNING: In order to avoid overheating do not cover the heater. The symbol on the product or in its packaging indicates that this product may not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment.
Need help?
Do you have a question about the ECOHHR20 and is the answer not in the manual?
Questions and answers
Hi Can the unrestricted supply be via a socket,switched spur or fused outlet?
No, the Gabarron ECOHHR20 storage heater requires two electrical supplies: an economy tariff supply (off-peak or restricted) and a 24-hour supply (on-peak or unrestricted). The economy supply must be connected via a 20A double pole isolator switch, while the 24-hour supply must be connected via a fused double pole isolator switch or a fused RCD isolator switch. Therefore, it cannot be supplied via a standard socket, switched spur, or fused outlet.