RELOCATION

WARNING: Relocation to another location must be carried out by an experienced
!
technician.
If during reinstallation the thermal insulation shows any sign of damage, it must be removed and replaced by an
identical part.

MANUALLY RESET TEMPERATURE LIMITER

MANUALLY RESET TEMPERATURE LIMITER
!
This heater employs a manual reset temperature limiter (see LR in the connection diagram).
This safety device operates when high temperatures are reached at the top of the heater. It requires re-setting
manually: Let the heater cool. The cause of overheating should be investigated.
WARNING: Re-setting manually must be carried out only by an experienced technician.
Turn off the heater at the circuit breaker.
Take off the front panel by removing the two screws located at the bottom. Find the limiter LR in the connection
diagram and push the small pin until a click is heard.

MAIN COMPONENTS LIST

Storage Heating Element
275W Balancing Element (ECOHHR20)
410W Balancing Element (ECOHHR30)
550W Balancing Element (ECOHHR40)
110ºC Left Limiter
140ºC Right Limiter
140ºC Storage Limiter
160ºC Cut Out Manual Limiter
Elnur powered by Gabarrón | ECOMBI HHR | Installation Guide
Ref. 10190410
Switch
Ref. 15192000
Main PCB
Ref. 15192002
Keyboard PCB
Ref. 15192004
Core Sensor
Ref. 15190725
Air Sensor
Ref. 15190720
Room Sensor
Ref. 15190720
Fan (ECOHHR20)
Ref. 15190730
Fan (ECOHHR30 & ECOHHR40)
Ref. 46100530
Ref. 15192125
Ref. 15190060
Ref. 15192140
Ref. 15192145
Ref. 60100580
Ref. 15192636
Ref. 15192638