PUTTING THE SYSTEM INTO OPERATION
Note: The „Standard" column contains the values the individual parameters contain when the control unit is delivered.
Configuration lifting station:
1
Run-down time
0
Switch-on
0
delay
ON 1
140
OFF 1
130
LED-display
POWER
Configuration pumpstation:
1
Run-down time
0
Switch-on
0
delay
ON 1
450
OFF 1
180
LED-display
POWER
How do I access the parameter setting mode?
Keep the „Alarm" and „Pump" keys pressed simultaneously for 5
seconds
an acoustic signal is given and the POWER LED flashes slowly,
you are in the first line (= run-on time)
the subsequent permanent flashing of the LEDs shows which co-
lumn you are in (which value is set), compare with the above table
Note: The parameter setting mode is quit automatically after 2 mi-
nutes without a key being pressed.
Settings can be made as follows:
How can I change the line?
Keep the „Alarm" and „Pump" keys pressed simultaneously again
for 5 seconds
an acoustic signal sounds and the line is indicated by the LED
combination lighting up once
permanent flashing of the LEDs shows which column you are in
(which value is set), compare with the above table
How can I change the column (change the value)?
Press the „Alarm" key once and you will move on to the next column
(shown by changed LED signals)
permanent flashing of the LEDs shows which column you are in
(which value is set), compare with the above table
Example video on Youtube under the link http://youtu.be/Ud9PAK3B3a8
2019/05
2
3
4
1
2
3
1
2
3
150
160
170
135
140
145
POWER
ALARM
ALARM
ALARM
LEVEL
2
3
4
1
2
3
1
2
3
500
520
530
200
220
240
POWER
ALARM
ALARM
ALARM
LEVEL
5
6
7
4
5
6
4
5
6
180
190
200
150
155
160
LEVEL
LEVEL
PUMP
PUMP
5
6
7
4
5
6
4
5
6
540
550
600
260
280
300
LEVEL
LEVEL
PUMP
PUMP
How do I save my setting?
Press the „Pump" key once
an acoustic signal sounds (value has been changed)
Note: Set-up mode is not quit by simply pressing the „Pump" key
How do I leave the parameter setting mode?
First possibility:
Second possibility: If the setting is not to be saved: Do not press any
an acoustic signal sounds and parameter setting mode has been
quit.
43/168
Unit
Standard
Seconds
1
Seconds
1
mmH
O
Mono 180/Duo 200
2
mmH
O
160
2
Unit
Standard
Seconds
1
Seconds
1
mmH
O
530
2
mmH
O
220
2
If the setting is to be saved: Press the „Pump"
key for 3 seconds
key for 2 minutes