9. Admin settings (installer parameters)

To enter admin settings (installer parameters) please follow steps below. Please refer to parameters table description before any changes.
Use
or
buttons to move up or down between all parameters. Every change/selection confirm by
1
Press
button to enter the
main menu.
Parameter name
TEMPERATURE SCALE
DISPLAY TEMP RESOLUTION
HEAT CONTROL ALGORITHM
COOL CONTROL ALGORITHM
TRV ADVANCED CALIBRATION
2
Move
or
look for Admin Settings.
Parameter Values
CELSIUS ⁰C
FAHRENHEIT ⁰F
0.5 ⁰C / 0.1 ⁰C
1 ⁰F / 0.2 ⁰F
ITLC UFH
ITLC RAD
ITLC ELECT
SPAN +/- 0.25 ⁰C (0.5 ⁰F)
SPAN +/- 0.5 ⁰C (1 ⁰F)
THB ACTUATOR
SPAN +/- 0.25 ⁰C (0.5 ⁰F)
SPAN +/- 0.5 ⁰C (1 ⁰F)
OFF
AUTO SELECT
ON
3
buttons to
When you will find Admin settings
then enter by
Description
This parameter specifies temperature unit of the thermostat.
This parameter specifies the accuracy of the displayed
(measured) temperature.
This parameter defines the algorith of the room temperature
control.
ITLC algorithm ensures reduction of overdrive states and
economic operation of the system. It is an advanced algorithm
designed to precisely maintain room temperature.
ITLC UFH - algorithm designed for underfloor heating (for
heating systems with high inertia),
ITLC RAD - algorithm designed for radiator heating,
ITLC ELECT - algorithm for electric heating (for heating systems
that heat up quickly and cool down quickly)
SPAN +/- 0.25⁰C (+/- 0.5⁰F)
SPAN +/- 0.5⁰C (+/- 1.0⁰F)
THB ACTUATOR - an algorithm designed for underfloor
heating systems which are equipped with THB actuators with
automatic flow balancing function (dynamic flow control).
The THB actuator has two temperature sensors that are
installed on the supply and return of the corresponding loop of
the underfloor heating. The self-regulating actuator measures
temperature on the sensors and adjusts its work to maintain
the correct temperature difference between the supply and
return flows(ΔT).
This parameter defines SPAN setting for cooling mode.
This parameter is only available when thermostat is paired with
the TRV head. This function runs an advanced self-learning
algorithm for systems not equipped with the RX10RF receiver.
System performs very accurate calibration of TRV head in order
to self-adapt to room conditions.
OFF
This option should be used in a system equipped with the
RX10RF (RX1) module to control the boiler. The advantage of
button:
button.
Default
Values
⁰C
0.5⁰C / 1⁰F
ITLC UFH
SPAN +/-
0.25 ⁰C /
0.5 ⁰F
AUTO
SELECT
61