6. Installer parameters

To enter installer parameters please follow steps below. Please refer to parameters table description before any changes. Use
up or down between all parameters. Every change/selection confirm by
1
3 sec.
Hold +
to enter the installer mode.
3
Press
button to confirm.
dXX
Function
d01
Heating Control
d02
Room temp. offset
d03
OUT sensor probe (S1/S2)
d04
Air sensor or Floor sensor
3 sec.
buttons for 3 seconds
Parameter
Values
This parameter defines the algorithm of the room temperature control.
0
1
2
-3.0°C to
+ 3.0°C
0
1
0
1
button:
2
Use
4
Select installer parameter by or
buttons. Use
change parameter value.
Confirm choice by
PWM (Pulse-width modulation) algorithm ensures reduction of overdrive
states and economic operation of the system. It is an advanced algorithm
designed to precisely maintain room temperature.
SPAN ± 0.25°C (± 0.5°F)
SPAN ± 0.5°C (± 1.0°F)
Offset room temperature measuring is a function which allows user to
recalibrate internal thermostat's temperature sensor by a given number of
degrees (in the range from -3,0 °C to 3,0 °C in 0,5°C steps).
Out sensor probe not connected
Out sensor probe connected
Air sensor: If parameter d03 is inactive (d03 = 0) then internal sensor
controls the temperature
Air sensor: If parameter d03 is active (d03 = 1) then internal sensor is
disabled and OUT sensor controls the temperature
Floor sensor: If parameter d03 is inactive (d03 = 0) then internal sensor
controls the temperature
Floor sensor: If parameter d03 is active (d03 = 1) then internal sensor is
disabled and OUT sensor controls the floor protection temperature
or
to choose
code „49".
3
or
buttons to
button.
Description
or
buttons to move
Default
Values
0
0.0°C
0
0
25