Installer Mode

3 sec
Press three buttons at the same time
for 3 seconds
To exit Installer Mode, wait 10 seconds, the thermostat will automatically return to the main screen.
dxx Function
d01
Temperature display increments
d02
Temperature offset
d03
Frost protection setpoint temperature
d04
TPI or SPAN algorithm selection
TPI = self-adaptive algorithm
SPAN = hysteresis (fixed temperature deviation)
d05
TPI or SPAN adjustment (if you selected SPAN
in parameter d04, then parameter d05 will
display the SPAN settings, the same applies to
the TPI algorithm)

Battery replacement

Reset of the DT300/DT300RF thermostat
3 sec
3 sec
Parameter value Default value
0.1 °C or 0.5 °C
+/- 3.0°C
5.0 °C - 17.0 °C
TPI or SPAN
6CP or 9CP /
0.25 °C or 0.5 °C
To insert and replace the batteries, follow the steps below:
1. Unlock the battery compartment.
2. Push the battery holder at the bottom of the thermostat
3. After adding or replacing the batteries, re-insert the battery
holder.
Press
to edit the parameter.
To change the parameter value
use
and
buttons.
0.5 °C
0.0 °C
5.0 °C
TPI
6CP / 0.5 °C
Press the RESET button under the
back cover (you can use a paper clip),
the thermostat will reset and restart
automatically.