3.7 Trigger switch setting (K5 level)

K5 level Flexlite GX welding guns are designed and set up for Kemppi Fastmig equipment. The trigger switch setting
described here, provides only limited support for other than Kemppi Fastmig welding equipment. Use this option with
caution.
Tools needed:
TX6
1.
Detach the trigger switch. Refer to "Trigger switch replacement" on page 18 for more detailed instructions.
2.
Release the small screw holding the trigger switch circuit board and remove the circuit board.
3.
Using the tip of a small screwdriver, set the two dip switches on the circuit board to ON.
4.
Reassemble and reinstate the trigger switch. Refer to "Trigger switch replacement" on page 18 for more detailed
instructions.
By default, the K5 level Flexlite GX welding gun models are set up for Kemppi Fastmig support.