SECTION 4 - MACHINE OPERATION

Platform Load Sensing System (LSS)

The Platform Load Sensing System provides the platform capac-
ity to the control system.
If the LSS system senses an overload condition, boom functions
will be disabled, the overload indicator is illuminated at both con-
trol stations, and the overload alarm will sound. Reduce the
weight in the platform to not exceed the rated workload indi-
cated on the capacity decal, then the controls will work again.
4-2

Stability

Machine stability is based on two (2) conditions which are called
FORWARD and BACKWARD stability. The machine's position of
least FORWARD stability and its position of least BACKWARD sta-
bility are shown below.
TO AVOID FORWARD OR BACKWARD TIPPING, DO NOT OVERLOAD MACHINE OR OPER-
ATE THE MACHINE BEYOND THE LIMIT OF THE MAXIMUM OPERATING SLOPE.