Controller Does Not Lite Up; Dirty Filling - CBE 510 Safety, Installation, Operation, Maintenance

Bulk bagger
Table of Contents

Advertisement

Controller doesn't lite up.
Check to make sure the Power switch is "on". Switch is located on the PLC enclosure.
Check 110v fuse on transformer is good. R/R if bad
Check E-stop – make sure it is pulled out.
Check round in- line fuse in the GSE controller. R/R if bad
Check for loose wire.
Bad LED display board

Dirty filling:

Insufficient dust collection pickup volume.
Bag seal not inflated enough. Material bypassing the seal.
Operator not putting the bag neck on the fill spout far enough.
Bad bag seal
Trouble shoot a Bad Load Cell:
SHIELD
EXCITION +
SIGNAL +
SENSE +
LOAD CELL CONNECTION GUIDE
CLEAR EXCITION +
RED
SIGNAL -
GREEN
SENSE -
BLUE
48
BLACK
WHITE
BROWN