Deployment
Counter - Functions
Count Periodically
50
Limits
Limit value
Upper count limit
No main counting direction
n
The counter counts forward or backwards starting with the load value.
n
At over- or underrun at the count limits, the counter jumps to the according other
count limit and counts from there on.
n
The count limits are set to the maximum count range.
Limits
Lower count limit
Upper count limit
Main counting direction forward
n
The counter counts forward starting with the load value.
When the counter reaches the end value –1 in positive direction, it jumps to the load
n
value at the next positive count pulse.
Valid value range
-2 147 483 648 (-2
31
)
to +2 147 483 646 (2
31
-2)
+2 147 483 647 (2
31
-1)
Valid value range
31
-2 147 483 648 (-2
)
31
+2 147 483 647 (2
-1)