YASKAWA VIPA SLIO FM 050-1BB00 Manual page 42

Counter module 2x32bit
Table of Contents

Advertisement

Deployment
In-/Output area > Input area 12byte
CV_I CV_II Counter value
CSTS_I CSTS_II Counter
status
42
Addr.
Name
+8
CSTS_I
+10
CSTS_II
The counter value always contains the current value of the corresponding counter.
Bit
Name
0
-
1
STS_CTRL_COMP
2
STS_SW-GATE
3 ... 4
-
5
STS_GATE
6
STS_COMP
7
STS_C_DN
8
STS_C_UP
9
STS_CMP*
10
STS_END*
11
STS_OFLW*
12
STS_UFLW*
13
STS_ZP*
14 ... 15
-
*) The bits remain set until reset with RES_SET (bit 6 control word).
Bytes
Function
2
Counter 0:
Counter status
2
Counter 1:
Counter status
Function
reserved
is set when comparison bit is enabled
Status software gate
(set when SW gate is active)
reserved
Status internal gate
(set when internal gate is active)
Status comparison bit
Status set
at counter direction backward
Status set
at counter direction forward
Status comparison is set when the comparison
condition is met.
If comparison is parameterized never, the bit is
never set.
Status is set
when end value was reached
Status is set at overflow
Status is set at underflow
Status is set at zero run
reserved
VIPA System SLIO
IX
5402h/s
5402h/s+1
HB300 | FM | 050-1BB00 | en | 19-38
SX
03h
04h