Troubleshooting Guide; Led Status Chart - Sensata Dimensions 12LP15 Owner's Manual

Dc to ac power inverter/charger pure sine wave output
Hide thumbs Also See for Dimensions 12LP15:
Table of Contents

Advertisement

 

TROUBLESHOOTING GUIDE

 
WARNING: Do not remove chassis cover. No user-serviceable parts
inside. Call or e-mail customer service for free consultation
during business hours. Business hours are 7:30am-5:30pm C.S.T
Phone: 1-800-553-6418 or 1-651-653-7000
Fax: 1-888-439-3565 or 1-651-653-7600

LED Status Chart

 
LED Color & State 
Green – 1 blink 
Green – 2 blinks 
Green – 3 blinks 
Green – 4 blinks 
Green – 5 blinks 
Green – 6 blinks 
Green ‐ Solid 
None 
Amber ‐ Solid 
Red ‐ Solid 
Red‐ 1 blink 
Red – 2 blinks 
Red – 3 blinks 
Red – 4 blinks 
Red – 5 blinks 
Red – 6 blinks 
Red – 7 blinks 
Red – 8 blinks 
None 
Amber‐ 1 blink 
Amber – 2 blinks 
Amber – 3 blinks 
Amber – 4 blinks 
Amber – 5 blinks 
Amber – 6 blinks 
Amber – 7 blinks 
Amber – 8 blinks 
Amber – 9 blinks 
Amber – 10 blinks 
Faults marked with* will self‐recover when the condition returns to normal range 
Faults marked with ** may be due to a short‐circuited output or a low or weak DC voltage source. 
Battery Type Local LED States at Start‐up (5 Minutes) 
Amber ‐ Green 
Amber – Green ‐ Green 
Amber – Green ‐ Green ‐ Green 
Table 7 - LED Status
Note:
Upon initial start-up, the inverter will blink amber and green to identify the type
of battery it is configured for.
 
 
E-mail: inverterinfo@sensata.com;
Website:
Status LED Normal States 
Remote LED State 
Constant on 
Constant on 
Constant on 
Constant on 
Constant on 
Constant on 
Constant on 
 Inverter Status LED Fault States 
Off 
Constant on 
Constant on 
1 blink 
2 blinks 
3 blinks 
4 blinks 
Feedback Fault, Output Short Circuit** 
5 blinks 
6 blinks 
7 blinks 
8 blinks 
Charger Status LED Fault States 
Off 
Fast blink 
Fast blink 
Fast blink 
Fast blink 
Fast blink 
Fast blink 
Charger Off – High Temp Transformer* 
Fast blink 
Fast blink 
Fast blink 
Fast blink 
26
122221 12LPC15 Manual Rev A.docx 
http://dimensions.sensata.com
Operating Conditions 
Bulk Charge (Constant Current) 
Accept Charge (Constant Voltage) 
Float Charge 
Load Management Active 
Equalization Mode 
Monitor Mode 
Inverting 
No Power to Unit or Internal Fault 
Low Battery 0‐5 seconds (warning) 
Overload 0‐5 seconds (warning) 
Inverter Low Battery Shut Down** 
Inverter Overload Shut Down 
High Temp Heatsink* 
High Battery 0‐5 minutes 
High Battery > 5 minutes 
High Temp Transformer 
Inverter Off by CAN 
No Power to Unit or Internal Fault 
Charger Off – Check Battery Probe 
Charger – Warm Battery* 
Charger Off – High Battery Voltage* 
Charger Off – High Batt Temp 
Charger Off – Low Battery Voltage 
Charger Off – High Temp Heatsink* 
Charger Off – 0 Amp Limit Set 
Charger Off –Overcurrent Shutdown 
Charger Off – Disabled by CAN 
Wet Lead‐Acid 
AGM 
GEL 