5. TROUBLESHOOTING

5.01 Sensata offers free phone consultation
concerning installation or troubleshooting.
Call the Customer Service Department at:
1-800-553-6418 or 651-653-7000
fax: 1-651-653-7600
e-mail: inverterinfo@sensata.com
5.02 If the inverter fails to operate, use the
following troubleshooting procedure.
5.02.1 Connect a 100 watt light bulb to the
inverter 120VAC, 60Hz output.
5.02.2 Make sure that the inverter is turned
"On", and the circuit breakers are reset.
5.02.3 Observe the fault indicating lights on
the front of the inverter.
a) The Low input voltage light indicates a low
battery condition. Switch the inverter "Off" for 5
seconds, then "On" again. The light coming on
again indicates a fault in the battery wiring, battery
capacity and voltage or the line fuse.
b) The Overload light indicates an output
wiring short circuit or a load that is too large for the
power rating of the inverter. Switch the inverter
"Off", remove the short circuit or excessive load
from the output, then switch the inverter back
"On".
c) The High temperature light indicates the
inverter has overheated. The unit will automatically
turn back on when it has cooled to 40
that the inverter is not in a closed compartment and
that the fan is not blocked.
5.03 Call Sensata for technical assistance and/
or a return authorization number if the above steps
are completed and the inverter still will not operate
satisfactorily.