Maintenance and Troubleshooting

4.0 Maintenance and Troubleshooting

The following information is provided to help you keep your MS-G Series inverter/charger in
optimum operational condition.
4.1

Recommended Inverter and Battery Care

The MS-G Series inverter/charger is designed to provide you with years of trouble-free service.
Even though there are no user-serviceable parts, it is recommended that every 6 months you
perform the following maintenance steps to ensure optimum performance and extend the life of
your batteries.
WARNING: Prior to performing any checks, switch OFF both the AC and DC circuits.
Visually inspect the batteries for cracks, leaks, or swelling—replace if necessary
Use baking soda to clean and remove any electrolyte spills or buildups
Check and tighten all battery hold-down clamps (if applicable)
Clean and tighten all battery terminals and connecting cables [10 to 12 lbf-ft (13.6 to 16.3
N-m)]
Check and fi ll battery water levels (liquid lead acid batteries only)
Check individual battery voltages (load test those that have a voltage difference of more
than 0.3 VDC from each other)—replace if necessary
Check all cable runs for signs of chafi ng—replace if necessary
Check the inverter's cooling vents—clean as necessary
Check and tighten the inverter's internal AC terminal block connections [16 lbf-in (1.8
N-m)]
4.2

Storage for Mobile Installations

When placing the RV, boat or truck into storage, it is recommended that you perform the following
to ensure the system is properly shut down (or properly confi gured for storage). This is especially
important for maintaining the batteries.
Perform the recommended maintenance steps listed in Section 4.1
Fully charge the batteries
Connect AC power (if available) and verify that the breaker to the inverter's input is
switched ON (to allow battery charging)
Verify the inverter is switched OFF
Switch OFF all unnecessary AC and DC loads
Disable the AGS (if installed) when the RV, boat, or truck is in a confi ned storage area
WARNING: If an AGS were to start and run the generator for an extended period
of time in a confi ned area, a potentially fatal level of CO (Carbon Monoxide) could
accumulate.