Physical Description - Sensata Dimensions 12LP15 Owner's Manual

Dc to ac power inverter/charger pure sine wave output
Hide thumbs Also See for Dimensions 12LP15:
Table of Contents

Advertisement

 

PHYSICAL DESCRIPTION

(1)
GFCI: Provides 120VAC output. Only replace with an approved GFCI.
(2)
Status LED: This LED will show inverter operation mode and troubleshooting
information. See the table in the troubleshooting section at the rear of the
manual for further operation mode descriptions.
(3)
Local On/Off: This switch turns the inverter on or off. **Switch inoperable
for "HR" and "R" configurations.
(4)
AC Input and Output Breakers: Input and output breakers. Protects the inverter
from output short circuits and overloads. The 12LP15 (inverter only) only uses
a 15A output breaker. The 12LPC15 (inverter/charger) uses 20A input and
output breakers. The input breaker position for the 12LP15 is plugged.
(5)
Bonding lug: Connects to the system ground.
(6)
DC input connections: Connects to the battery bank.
(7)
Remote On/Off Wiring Tab: Terminal is used to wire a customer supplied
remote ON/OFF switch. Apply battery voltage to tab to turn on inverter.
(8)
Aux Wiring Tab: Terminal is used to enable internal housekeeping power
only. Apply battery voltage to enable. Does not turn on inverter output.
(9)
AC Wiring Access Plate: Provides wiring and inspection access to AC output
terminals inside the AC wiring box. To be closed during operations.
(10)
Various Ports: "CAN" is used for connection of a CAN interface. "TEMP
SENSE" is used for connection a battery temperature sensor (BTS), sold
separately. "ACC" is used for a remote switch (purchased separately). The Sync
port may be plugged with an empty connector because it is currently not used.
Figure 1 - Features
7 7
8 8
3 3
2 2
9
6 6
 
 
10 10
1
5 5
4
7
122221 12LPC15 Manual Rev A.docx 

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dimensions 12lpc15

Table of Contents