Self-Testing – The GFCI will periodically test the ground fault detection circuit in the
background. If the test determines there is a problem with the detection circuit, the
GFCI will trip and/or notify the user visually with the status LED. The GFCI will
perform a self-test when AC power is first applied to it. The LED will blink RED before
turning GREEN.
Line-Load Reversal – If the line and load terminals are wired backwards, the GFCI will
not reset and power will not be available until the wiring has been corrected.
 
NOTE: Depending on the GFCI model that is used, the line and load terminals
on the rear may not be in the same position. The user must verify the
GFCI markings to ensure proper connection.
NOTE: It is advisable when replacing a GFCI outlet to only use the exact
replacement part unless instructed to do otherwise by the factory.
Other types may fail to operate properly when connected to this unit.
NOTE: Ground-fault circuit-interrupters shall be installed in the recreational
vehicle wiring system to protect all branch circuits. 
GFCI MFG
CATALOG NO.
LEVITON
GFNT2-# (FOR #, I=IVORY, W=WHITE)
GFR5362SG# (FOR #, I=IVORY, W=WHITE)
HUBBELL
COOPER
TRSGF20# (FOR #, V=IVORY, W=WHITE)
Table 9 - GFCI Replacements.

Inverter Model Options

The following model options are available:
Table 10 - Options
OPTION
A
AC TERMINALS PROTECTED BY GFCI
H
HARDWIRE ONLY, NO GFCI.
R
REMOTE ONLY, LOCAL SWITCH INACTIVE

Other options available, contact the factory for more information.

 
 