NOTE: While in sleep mode it may take up to one second for the load to receive
power when the load is applied.
NOTE: The LED on the GFCI will blink when the inverter has gone to sleep.
Auxiliary Control
The "AUX" tab on the side of the inverter allows for additional functionality of the
inverter. The "AUX" tab is set to disabled by default at the factory. To change it,
contact the factory or use the CAN Setup Tool. To use the AUX tab, battery voltage
needs to be applied to it. The connection should be fused.
Mode
Disabled
Utility
RV
Control
Table 6 - Aux Control
The "AUX" tab has no effect on charger and bypass functions if enabled on a 12LP15
inverter only.
Note: Applying battery voltage to the "AUX" tab while the inverter is off will cause the
inverter to draw about 170mA. Remove power from the "AUX" tab when not
using the inverter to conserve battery power.
REMOTE
REMOTE
IGNITION
IGNITION
FUSE
FUSE
SWITCH
SWITCH
12 Vdc
12 Vdc
BATTERY
BATTERY
Figure 9 - Aux Connection
Battery Options
The charger can be set to charge three different types of batteries. Wet Lead Acid, AGM,
or Gel. The charger is set to Wet Lead Acid by default by the factory. The battery type
may be changed at the factory or by the CAN configuration interface. To determine what
type of battery the inverter is configured for, monitor the LED blink code at startup. If
the inverter is configured for Wet Lead Acid, the LED will blink Amber-Green. For
122221 12LPC15 Manual Rev A.docx
Description of Mode
Aux tab doesn't do anything.
Aux tab required to be high to enable inverter, charger,
and bypass.
Aux tab required to be high to enable inverter. Charger
and bypass not affected.
Aux tab required to be high to enable charger mode.
Inverter and bypass not affected.