To make your own "Inverter Cable Kit," follow the below recommendations:
1.
Use 1/0-ga stranded copper cables in all cases.
2.
USE SGX cross-linked polyurethane insulation type that complies with the high
temperature insulation requirements (125°C.) of SAE J-1127 and vehicle
manufacturer requirements.
3.
For 1/4" ring lugs, use JST 38-S6.
TIP: It is useful to use a needle nose pliers to help insert or remove the 1/4x20 screw
and toothed washer.
Figure 3 - Proper installation of cable into DC terminal cover
122221 12LPC15 Manual Rev A.docx
10