1) How to set up in/output configuration according to number of doors.
Solution
① IN/OUTPUT Configuration for 1~2 Door Control (Basic Configuration)
※ 2 Doors / Using In Reader Only (2 Readers) :
2 Doors / Using In-Out Reader (4 Readers) :
Input Ports #4
 Door Contact for Door 2
 Output to Output Port #4
Input Ports #3
 Exit Button for Door 2
 Output to Output Port #3
Input Ports #2
 Door Contact for Door 1
 Output to Output Port #2
Input Ports #1
 Exit Button for Door 1
 Output to Output Port #1
Connect to iTDC Main Board
Same with Configuration of Door 1 & 2 for 3 Door Control
iTDC Main Board
(Refer to Next Page)
Output Ports #1
 Door Lock for Door 1
 Input Port #1,
Output for Reader #1
Output Ports #2
 Alarm for Door 1
 Input Port #2,
Output for Reader #1
Output Ports #3
 Door Lock for Door 2
 Input Port #3,
Output for Reader #2
Output Ports #4
 Alarm for Door 2
 Input Port #4,
Output for Reader #2