DME24N/DME64N

ERROR MESSAGES

Message
Error messages
Cannot Select
Flash Rom Full
Invalid Password
Low Battery
MIDI Port In Use
No Battery
Param Access Err
Param Set Err
Saving Failed
Slots Overloaded
Store Disable
Status messages
CAS. In Sync Err
CAS. Out Sync Err
Connecting
Download Success
Downloading
Duplicate IP Adr.
File Operating
Illegal MAC Adr.
Invalid IP Adr.
Network Busy
Network Error
Network Setup
No Current Scene
No MAC Adr.
Panel Locked
Panel Unlocked
Recovering
Saving HA Info
142
Meaning
No selectable items are available in the scene or
monitoring point list display.
The flash ROM is full.
An invalid password has been entered.
The backup battery voltage is low.
The MIDI host setting is set to the same setting as the
DME Designer application.
The battery is completely depleted.
Current setting cannot be displayed.
Current setting cannot be changed.
A save operation has failed.
The current being used by all cards installed in I/O slots
exceeds the rated limit.
The scene store parameter is set to "Disable."
The DME64N/24N clock is not in sync with the clock
signal being received at the [CASCADE IN] connector.
The DME64N/24N clock is not in sync with the clock
signal being received at the [CASCADE OUT] connector.
Connecting to the network.
The DME64N/24N program has been successfully
updated.
DME64N/24N program update in progress.
Duplicate IP addresses.
A file operation in which the computer is manipulating
scene data (including configuration and component
data) is in progress.
An illegal MAC address has been encountered.
The network ID address is not appropriate.
There is too much network traffic. Communication is not
possible.
One of the following errors has occurred on the network:
• A cable has been unplugged.
• The power to a hub or router has been shut off.
• A cable is in an inappropriate state (e.g. a heavy object
has been placed on the cable, etc.). Static electricity
can also cause errors.
Preparing network connection.
There is no data in the current scene.
MAC address not specified.
Panel operation not allowed.
Panel lock has been disengaged. Panel operation is now
possible.
A DME64N/24N program update attempt has failed, and
the previous program is currently being restored.
(Do not turn power off.)
Head amplifier info save in progress.
(Do not turn power off.)
Action
Make the appropriate settings via the DME Designer
application.
Reduce the number of stored scenes.
Enter the correct password.
Stop using the device immediately.
Set the Utility MIDI page "Host" parameter to a different
port.
Stop using the device immediately.
Try again.
Try again.
Stop using the device immediately.
Re-install the cards so that the current limit is not
exceeded.
Set the scene store parameter to "Enable" via the Utility
display "Lock" page.
Set the device connected to the [CASCADE IN]
connector and the DME64N/24N to use the same word
clock.
Set the device connected to the [CASCADE OUT]
connector and the DME64N/24N to use the same word
clock.
None required.
None required.
None required.
Change the IP addresses so that there are no duplicates.
None required.
This could be due do a hardware malfunction.
Set an appropriate network ID address.
Check the devices connected to the network. If there are
too many devices connected, reduce the number of
devices.
Locate and eliminate the cause of the error.
None required.
Send appropriate scene data from a computer running
the DME Designer application.
This could be due do a hardware malfunction.
Press the [CANCEL] button for longer than 2 seconds to
disengage panel lock and allow panel operation.
None required.
After the program has been restored, try the update
operation again. If repeated update attempts fail, a
hardware malfunction may be the problem.
None required.