Gpi Test; Result Display Screen - Yamaha DME24N Service Manual

Digital mixing engine
Hide thumbs Also See for DME24N:
Table of Contents

Advertisement

Messages
· When asynchronous internal word clock is detected:
NG: INTERNAL UNSYNC ERROR
· When asynchronous external word clock is detected:
NG: EXTERNAL UNSYNC ERROR
· When slot initialization error is detected due to
selection of external word clock MY-SLOT1-4 (EXT2-
EXT4):
NG: MY-SLOT INITIAL ERROR
· When unlock is detected:
(Note1)
The details of external input word clock selection
display are as follows.
Display
External input word clock
EXT1
BNC
EXT2
MY-SLOT1
EXT3
MY-SLOT2
EXT4
MY-SLOT3
EXT5
MY-SLOT4
EXT6
CASCADE IN
EXT7
CASCADE OUT

1-14. GPI Test

Content: The GPI output and the GPI input are loop
back connected via a special-purpose test jig, and the
GPI input voltage is measured to automatically check
for normality. The GPI output has two voltages, namely
L/H. The test result shows the L/H voltages for all
channels. DME64 shows the L/H voltages for 16
channels, while DME24 shows for 8 channels.
Executing Screen
∗∗∗
14.
GPI
GPI Loopback Testing...
Fig. 33. GPI Test Screen (1)
NG: UNLOCK ERROR
Selecting Condition
Cannot select on DME24N.
Cannot select on DME24N.
Cannot select on DME24N.
Cannot select on DME24N.
Cannot select on DME24N.
∗∗∗

Result Display Screen

∗∗∗
14.
GPI
CH No.
Lo [V]
Hi [V]
CH1
1.200
3.140
CH2
1.200
3.140
CH3
1.201
3.139
CH4
1.205
3.141
CH5
1.203
3.140
CH12
1.200
3.140
CH13
1.200
3.140
CH14
1.201
3.139
CH15
1.205
3.141
CH16
1.203
3.140
GPI OK!
EXIT: [ENTER]
CH12
1.200
3.140
CH13
1.200
3.140
CH14
1.201
3.139
CH15
1.205
3.141
CH16
1.203
3.140
NG: GPI CH ERROR!
EXIT: [ENTER]
Fig. 34. GPI Test Screen (2)
Using an encoder, the result display screen is scrolled.
DME24N/DME64N
∗∗∗
Scroll Display
Indicated in case of O.K.
Indicated in case of NG.
111

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dme64n

Table of Contents