Yamaha DME24N Service Manual page 143

Digital mixing engine
Hide thumbs Also See for DME24N:
Table of Contents

Advertisement

Message
Saving Setup Info
Info set up via the Utility display (other than head
amplifier info) is being saved.
(Do not turn power off.)
Scene Recalling
Scene recall in progress.
Scene Storing
Scene store in progress.
(Do not turn power off.)
SLOT1 Sync Err
The DME64N/24N clock is not synchronized with the
clock of the card installed in I/O slot 1.
SLOT2 Sync Err
The DME64N clock is not synchronized with the clock of
the card installed in I/O slot 2.
SLOT3 Sync Err
The DME64N clock is not synchronized with the clock of
the card installed in I/O slot 3.
SLOT4 Sync Err
The DME64N clock is not synchronized with the clock of
the card installed in I/O slot 4.
WCLK Unlocked
A usable word clock signal is not being received or
cannot be detected.
Zone Sync Err
The DME64N/24N contains data of another zone or no
data.
Meaning
Action
None required.
None required.
None required.
Make sure that the DME64N/24N and the card installed
in I/O slot 1 are set to use the same word clock.
Make sure that the DME64N and the card installed in I/O
slot 2 are set to use the same word clock.
Make sure that the DME64N and the card installed in I/O
slot 3 are set to use the same word clock.
Make sure that the DME64N and the card installed in I/O
slot 4 are set to use the same word clock.
Recheck all word clock connections and internal
parameters.
Send appropriate data from a computer running the DME
Designer application,