Yamaha DME24N Service Manual page 139

Digital mixing engine
Hide thumbs Also See for DME24N:
Table of Contents

Advertisement

1-1-4. Check the DME you wish to update, then click
the [Update] button.
The firmware update will begin.
While updating, be very careful not to disconnect the
USB or Ethernet cable or turn off the power to the DME.
The DME Designer MIDI setting information will be lost.
When the DME update is finished, the DME unit will be
automatically restarted. You also need to restart DME
Designer.
[Component]
Updates the DME unit component firmware. When you
select this command, the "Open" dialog box will be
displayed. Opens update files with the extension ".DCB"
(for DME) or ".CCB" (for ICP1). You can select multiple
update files for components.
[DME Unit]
When performing the firmware update, connect the DME
unit and the computer by USB or Ethernet. The USB-
MIDI or DME-N Network driver must be installed in the
computer.
[ICP1]
To perform the firmware update, the ICP1 and the zone
master DME unit must be connected by Ethernet. In
addition, the zone master DME unit must be connected
to the computer as described above.
1-2-1. Select [Firmware Update]
[Tools] menu.
The "Open" dialog box will be displayed.
[Component] in the
1-2-2. Select an update program with the extension
".DCB" (for DME) or ".CCB" (for ICP1) and click
the [Open] button.
The "Firmware Update" dialog box will be displayed.
The DMEs or ICPs in the current zone will be
displayed in a list. The component names and
versions will be displayed hierarchically for each
DME.
1-2-3. Check the component you wish to update.
You can click on the checkmark to turn it ON/OFF.
The [Select All] button places a checkmark next to
all the DMEs. The [Clear All] button turns OFF all
the DME checkmarks.
1-2-4. Check the component you wish to update, then
click the [Update] button.
The component update will begin.
While updating, be very careful not to disconnect the
USB or Ethernet cable or turn off the power to the DME.
The DME Designer MIDI setting information will be lost.
When the DME update is finished, the DME unit will be
automatically restarted. You also need to restart DME
Designer.