Pepperl+Fuchs IPT-HH20 Manual page 76

Handheld (125 khz)
Table of Contents

Advertisement

IPT-HH20
Software description PF_Ident
Instructions on Overwrite tag function
Fill tag
1.
Select Read/Write > Fill tag > Data.
2.
Press the CLEAR input key (
the last character entered, not individual characters within the character string.
3.
Enter the value for overwriting the data carrier in the correct syntax for the data format
selected using the input keys.
4.
Press the left softkey (
If the character entered does not correspond with the syntax of the data format, an error
message is issued and the value is not accepted.
5.
Position the read/write head on the Handheld directly beside the data carrier.
6.
Press the left softkey (
If the read process is successful, "OK" appears on the display and the status LED flashes
green. If you have activated the buzzer and the vibration alarm in the Settings menu, an
acoustic signal sounds and the Handheld vibrates. The read data is then displayed in line with
the selected data format. If the transfer was unsuccessful, the status LED briefly flashes red
and a fault indication is issued. See see chapter 8