Pepperl+Fuchs IUH-F117-V1-EU Manual
Pepperl+Fuchs IUH-F117-V1-EU Manual

Pepperl+Fuchs IUH-F117-V1-EU Manual

R/w head for identcontrol
Hide thumbs Also See for IUH-F117-V1-EU:

Advertisement

Quick Links

FACTORY AUTOMATION
MANUAL
IUH-F117-V1-EU
IUH-F117-V1-US
IUH-F117-V1-CN
R/W head for IDENTControl

Advertisement

Table of Contents
loading

Summary of Contents for Pepperl+Fuchs IUH-F117-V1-EU

  • Page 1 FACTORY AUTOMATION MANUAL IUH-F117-V1-EU IUH-F117-V1-US IUH-F117-V1-CN R/W head for IDENTControl...
  • Page 2 IUH-F117-V1-* With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services of the Electrical Industry, published by the Central Association of the Electrical Industry (Zentralverband Elektrotechnik und Elektroindustrie (ZVEI) e.V.) in its most recent version as well as the supplementary clause: "Expanded reservation of proprietorship"...
  • Page 3: Table Of Contents

    IUH-F117-V1-* Contents 1 Introduction................. 5 2 Declaration of Conformity ..........6 3 Safety ................... 7 Symbols relevant to safety ................7 Intended Use ....................7 General notes on safety.................8 4 Product Description ............9 UHF general ....................9 4.1.1 Advantages of UHF ..................9 4.1.2 Permissible Operating Capacity of UHF ...........9 4.1.3 Permissible Frequency Range of UHF............9 4.1.4 Applications for UHF systems..............9...
  • Page 4 IUH-F117-V1-* Contents 5 Installation ................ 21 Storage and transport................. 21 Unpacking ....................21 Mounting ....................21 5.3.1 Orientation in the room ................22 5.3.2 Minimum and Maximum Distances ............22 5.3.3 Polarization .................... 23 Connection....................24 EMC concept ..................... 24 6 Commissioning ..............
  • Page 5: Introduction

    Introduction Introduction Congratulations You have chosen a device manufactured by Pepperl+Fuchs. Pepperl+Fuchs develops, produces and distributes electronic sensors and interface modules for the market of automation technology on a worldwide scale. Before you install this device and put it into operation, please read the operating instructions thoroughly.
  • Page 6: Declaration Of Conformity

    Notice: Changes or modifications made to this equipment not expressly approved by Pepperl+Fuchs GmbH may void the FCC authorization to operate this equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
  • Page 7: Safety

    Pepperl+Fuchs GmbH provides no guarantee that the information contained in this document does not contain third party industrial property rights. Pepperl+Fuchs GmbH does not issue any licenses to its own or third party patents or other industrial property rights in this document.
  • Page 8: General Notes On Safety

    If serious faults occur, stop using the device. Secure the device against inadvertent operation. In the event of repairs, return the device to your local Pepperl+Fuchs representative or sales office. The connection of the device and maintenance work when live may only be carried out by a qualified electrical specialist.
  • Page 9: Product Description

    IUH-F117-V1-* Product Description Product Description UHF general 4.1.1 Advantages of UHF Large sensing range ■ UHF high-temperature transponder available for the automobile industry ■ UHF transponders are available as low-cost, space-saving adhesive labels ■ High transfer rates ■ Large quantities of data transferred, depending on the transponder ■...
  • Page 10: Memory Structure Of A Tag In Accordance With Iso 18000-6C/ Epc Class 1 Gen 2

    IUH-F117-V1-* Product Description 4.1.5 Memory Structure of a Tag in Accordance with ISO 18000-6C/EPC Class 1 Gen 2 [7:0] DSFID [7:0] Commands IUH-F117-V1-* Memory module [15:0] SR/ER Bank 11 USER [31:16] SW/EW Bank 10 SF/EF SS/ES Bank 01 UII/EPC SP/EP Optional XPC_W2 [15:0] Optional XPC_W2...
  • Page 11: Electronic Product Code Epc

    IUH-F117-V1-* Product Description Bank 00 The segment bank 00 contains the password manager, comprising the access password and the kill password. This range is not currently supported by IUH- F117-V1-*. Bank 01 In addition to the UII, the segment bank 01 contains a calculated checksum CRC (cyclic redundancy check) for verifying data on the tag and the protocol control (PC) range.
  • Page 12: Unique Numbering As Per Iso

    IUH-F117-V1-* Product Description GS1/EPCglobal developed the system of Electronic Product Codes (EPC) for use in resource planning. Transponders with a memory for EPC codes are programmed by the user. The memories of new transponders do not have to contain valid EPC codes. The EPC numbers are allocated and managed by GS1. If you require EPC numbers, please contact the respective GS1 branch in your country (http://www.gs1.com/contact).
  • Page 13: Influence Of Various Materials On The Sensing Range

    IUH-F117-V1-* Product Description UNIK describes the company, in this case "UNIK." 3. Serial number 15000905130035 is the unique serial number. The relevant standards relating to unique identification include ISO/IEC 15434, ISO/IEC 15459-1 to 8 and ISO/IEC TR 29162 (in preparation). 4.1.8 Influence of various materials on the sensing range In the UHF range, the nature of the surrounding area and the surface to which the...
  • Page 14: Countries Of Use

    Europe In line with EPC Global and ETSI EN 302208, only channels 4, 7, 10 and 13 are used in this mode for transmission for the IUH-F117-V1-EU read/write head (read/write head -> read/write tag communication path). The transmission power is max. 2 W Channel 865.0...
  • Page 15: Europe

    Product Description 4.1.11 Europe The IUH-F117-V1-EU read/write head has wireless approval to DIN EN 302208-2. The read/write head is operated in dense reader mode (DRM). This operating mode in accordance with the UHF Gen 2 specification allows several read/write heads to be operated next to each other in the permitted channels (4, 7, 10 and 13) without interference.
  • Page 16: Usa

    IUH-F117-V1-* Product Description 4.1.13 The ISM band from 902 to 928 MHz is available in the USA. The band is split into 50 channels, each with a 500 kHz bandwidth. FHSS with a maximum retention time of 4 seconds is employed. All channels must be used. Channel restriction is not permitted.
  • Page 17: General Functions And Features

    IUH-F117-V1-* Product Description General Functions and Features Functions The read/write head IUH-F117-V1-* was developed for writing and reading passive read/write tags with a UHF range operating frequency. Detection range An integrated, highly-sensitive transmission and receiver unit enables a read/write tag detection range of up to 6 meters and permits tag protocols in accordance with EPC Class1 Gen2 and ISO 18000-6 C.
  • Page 18: Connection

    Shield Scope of Delivery Read/write head IUH-F117-V1-* ■ Manual ■ Accessories 4.6.1 IDENTControl The IUH-F117-V1-* can be connected to Pepperl+Fuchs IDENTControl control interfaces as a read/write head. Interface Designation 4 read/write heads: Ethernet IC-KP-B17-AIDA1 2 read/write heads: Ethernet IC-KP2-2HB17-2V1D...
  • Page 19: Read/Write Tags

    IUH-F117-V1-* Product Description 4.6.2 Read/Write Tags Type Designation ISO 18000-6 C IUC72-C8-T14 IUC72-F151 IUC72-F152 IUC73-F153 IUC76-F157-M 4.6.3 Connection cable for R/W heads and trigger sensors Compatible connection cables with shielding are available for connecting the R/W heads and trigger sensors. Figure 4.5 Accessories Description...
  • Page 20: Cable Connectors For The Power Supply

    IUH-F117-V1-* Product Description 4.6.4 Cable connectors for the power supply Compatible M12 sockets with an open cable end for connecting the IDENTControl to a power supply are available in different lengths. Figure 4.6 Accessories Designation Length 2 m (straight socket) V1-G-2M-PUR Length 5 m (straight socket) V1-G-5M-PUR...
  • Page 21: Installation

    ■ Retain the original packaging in case you have to store or ship the device again at a later date. Should you have any questions, please contact Pepperl+Fuchs. Mounting Note! Please note that radio waves in the UHF range do not disperse evenly due to reflections on objects in the surrounding environment.
  • Page 22: Orientation In The Room

    IUH-F117-V1-* Installation 5.3.1 Orientation in the room The alignment of the antennas on the data carrier in relation to the antenna on the read/write head influences the sensing range of the system. Therefore, make sure that the antennas are aligned parallel to one another. Maximum sensing range Minimum sensing range 5.3.2...
  • Page 23: Polarization

    IUH-F117-V1-* Installation If you wish to position multiple read/write heads next to each other or above each other, the distance should be no less than 20 cm between each unit. A minimum distance of 50 cm is reasonable. min. 50 cm Figure 5.2 5.3.3 Polarization...
  • Page 24: Connection

    IUH-F117-V1-* Installation Polarization plane Figure 5.3 Polarization plane IUH-F117-V1-* with linear polarization Connection Connect the read/write head to the IDENTControl interface using a shielded connection cable (see chapter 4.6.2). Make sure that the shielding is continuous to prevent EMC interference. (see chapter 5.5) EMC concept The outstanding noise immunity of the IDENTControl against emission and immission is based on its consistent shielding design, which uses the principle of...
  • Page 25 IUH-F117-V1-* Installation The most important issue here is that the shields are connected to ground with low resistance and low inductance. The metal enclosure ensures that the shielding is not interrupted, i.e. the complete electronics system and all routed cables are located within a Faraday cage.
  • Page 26: Commissioning

    IUH-F117-V1-* Commissioning Commissioning Connection Caution! Uncontrollable triggered processes The plant where the device is installed may be damaged. Before commissioning, make sure that all processes run in a controlled manner. Warning! Incorrect electrical connection Damage to the device or system caused by incorrect electrical connection Check all connections in the plant before commissioning the device.
  • Page 27 IUH-F117-V1-* Commissioning Note! Hexadecimal format In the examples, hexadecimal values are displayed in .03 format. A period is followed by two characters of hexadecimal code. = <ETX> Commissioning the IDENTControl Compact Control Interface 1. On the PC, open a terminal program (e. g. "Hyperterminal" or the command in- put window of the "RFIDControl"...
  • Page 28 IUH-F117-V1-* Commissioning Note! The device makes no distinction between commands entered in upper and lower case. Make sure that there are no spaces in all parameters that come after the command. Example: In the examples below, the read/write head is connected to channel 1 of the control interface.
  • Page 29 IUH-F117-V1-* Commissioning Enhanced Read Read-Only Code Serial Ethernet PROFIBUS Command: .00.04.1D.03 .1D.03 Confirmation: .00.06.1D.03.FF.36 .1D.03.FF.36 Response: 01.E0.04.26.70.18. .00.0E.1D.03.00.37. .1D.03.00.37.E0.04. 01.00.00 E0.04.26.70.18.01. 26.70.18.01.00.00 00.00 Table 6.2 Tag in the detection range Describing Tags Set the tag type to IUC72. Do this by transmitting the command change tag (see "Change Read/Write tag CT"...
  • Page 30 IUH-F117-V1-* Commissioning Example of parameterization: Setting and requesting the read/write head's transmission power. Read out the read/write head's transmission power with the read param PT: Serial Ethernet PROFIBUS Command: RP1UPT .00.09.BE.03.55.50. .BE.03.55.50.54.00. 54.00.00 Confirmation: .00.06.BE.03.FF.3E .BE.03.FF.3E Response: 01.07.D0 .00.08.BE.03.00.3F. .BE.03.00.3F.07.D0 07.D0 Use the write param PT to change the read/write head's transmission power to 500 mW:...
  • Page 31: Operation

    IUH-F117-V1-* Operation Operation General The sections below contain the details on the commands that specifically address the read/write head IUH-F117-V1-*. The commands are described using the example of an IDENTControl control interface with serial interface. All other generally applicable commands and error or status messages can be found in the manual for your IDENTControl control interface.
  • Page 32 IUH-F117-V1-* Operation Enhanced Read Special Read-Only Code ES This command continuously attempts to read the UII segment of tags from type 72 (EPC Class 1 Gen2). If a UII is read, this is reported once to the control interface. If there is no UII in the detection range or if the tag leaves the detection range before the UII is read, a status 5 is reported to the evaluation unit as a response.
  • Page 33 IUH-F117-V1-* Operation Note! The memory bank MB parameter defines the bank which this command accesses. See "Memory Bank MB" on page 40. Enhanced Read Words ER An attempt is made until <WordNum> 32-bit words are successfully read from the address <WordAddr>. Only changing data is transferred via the interface. When a read/write tag leaves the read range, status 5 is output.
  • Page 34: Configuration Commands

    IUH-F117-V1-* Operation Note! 16-Bit Read/Write Commands The read/write commands SR, ER, SW and EW are interpreted as 16-bit versions by means of a preceding # symbol. The 16-bit read/write commands behave in the same way as the 32-bit versions. 16-bit commands write or read a word with a length of 2 bytes. ■...
  • Page 35: Readparam/Writeparam Commands

    IUH-F117-V1-* Operation Tag Types UHF 868 MHz Special Unique desig- Data Bank 00 read-only read-only type Chip type Details nation [bytes] [bit] code [bit] code EPC Class 1 NXP UCode- IUC72 E200600 32 + 32 Gen 2 EPC-G2XM 3 + serial number EPC Class 1 Alien Higgs-2...
  • Page 36: Paramtyp

    IUH-F117-V1-* Operation Read Param This command reads configuration parameters from the IQH2-... and IUH-F117- V1-* read/write head. Command: RP <ChanNo> <SystemCode> <ParamTyp> <ParamLength> <CHCK> <ETX> Response: <Status> <Data> <CHCK> <ETX> Syntax <SystemCode><ParamTyp> <ParamLength> Write Param This command writes configuration parameters to the IQH2-... and IUH-F117-V1-* read/write head.
  • Page 37 Power Transmit PT This parameter sets the transmission power in mW or reads out the set transmission power. The transmission power is stated for IUH-F117-V1-EU and IUH-F117-V1-CN in . The transmission power is stated in W for the read/write head IUH-F117- V1-US...
  • Page 38 Possible overreaches if the transmission power increases. Adjacent read/write heads might be affected if the range increases. Channel DRM CD (IUH-F117-V1-EU Only) This parameter sets the sequence of the channels permitted in the DRM (= dense reader mode) or reads out the sequence of the permitted channels. Only channels 4, 7, 10 and 13 are available.
  • Page 39 IUH-F117-V1-* Operation No distinct reading/writing when several tags are within the detection range, no warning message. Much more complex collision management when several tags are in the detection range. Q-Value QV The QV parameter controls the multi-tag operating mode for the read/write head. This operating mode controls the ability to deal with several read/write tags within the detection range.
  • Page 40: Legend

    IUH-F117-V1-* Operation Memory Bank MB This parameter specifies the bank which the read/write commands SR, ER, SW and EW access. ParamTyp: Default: MB = .03 = User Memory Value range: .01 = UII .02 = TID .03 = User Memory If Bank 01 (UII) is defined as the access range, the Control PC protocol can only be changed in 16-bit mode.
  • Page 41: Fault/Status Messages

    IUH-F117-V1-* Operation <SystemCode>: <Tagtype>: 2 ASCII characters <Timeout>: Interface timeout; an error message is sent after this time runs out <UII/EPC>: Unique Item Identifier, memory area of a tag in accordance with ISO 18000-6 C, in which the EPC code is stored, for example. <WordAddr>: Word start address in the read/write tag, 4 ASCII characters, range from ‘0000h’...
  • Page 42: Service And Maintenance

    IUH-F117-V1-* Service and Maintenance Service and Maintenance The device is designed and constructed to function stable over long periods of time. For this reason, regular cleaning or maintenance is unnecessary.
  • Page 43: Troubleshooting

    IUH-F117-V1-* Troubleshooting Troubleshooting Problem Solution Interference from several read/write heads Send the parameter CA ■ in the direct vicinity Change the channel setting ■ Reduce the transmitting power ■ Status 5 message even though Check the preset transponder type (see ■...
  • Page 44: Ascii Table

    IUH-F117-V1-* ASCII table ASCII table ASCII ASCII ASCII ASCII Space " & < >...
  • Page 45: Appendix

    IUH-F117-V1-* Appendix Appendix 11.1 Dimensions 300.5 11.2 Technical Data General specifications Device IUH-F117-V1-EU IUH-F117-V1-US IUH-F117-V1-CN Operating frequency 865.1 ... 867.9 MHz 902 ... 928 MHz 920.5 ... 924.5 MHz Radiated power 2 W ERP 4 W EIRP 2 W ERP...
  • Page 46: Detection Range

    IUH-F117-V1-* Appendix Ambient conditions Ambient -25 ... 55 °C (-13 ... 131 °F) temperature Storage temperature -25 ... 85 °C (-13 ... 185 °F) Mechanical specifications Protection degree IP54 Connection M12 x 1 connector Material Housing aluminum / ABS Mass approx.
  • Page 47 IUH-F117-V1-* Appendix Horizontaler Erfassungsbereich Winkel [Grad] 90 80 Abstand [m] Figure 11.1 Horizontal detection range with horizontal polarization Vertikaler Erfassungsbereich Winkel [Grad] 90 80 Abstand [m] Figure 11.2 Vertical detection range with horizontal polarization Curve 1 shows the detection range under optimum operating conditions with a transmission power of 2000 mW ERP.
  • Page 48 The time required for this repeat is allowed for when calculating a maximum speed under real conditions. The maximum speed in this case is therefore 150 km/h. Please consult Pepperl+Fuchs for specific data on read and write times, as well as passing speeds.
  • Page 49 IUH-F117-V1-* Appendix...
  • Page 50 Twinsburg, Ohio 44087 · USA Tel. +1 330 4253555 E-mail: sales@us.pepperl-fuchs.com Asia Pacific Headquarters Pepperl+Fuchs Pte Ltd. Company Registration No. 199003130E Singapore 139942 Tel. +65 67799091 E-mail: sales@sg.pepperl-fuchs.com www.pepperl-fuchs.com Subject to modifications Copyright PEPPERL+FUCHS • Printed in Germany TDOCT2077D_ENG 09/2012...

This manual is also suitable for:

Iuh-f117-v1-usIuh-f117-v1-cn

Table of Contents