Pepperl+Fuchs IPT-HH20 Manual page 61

Handheld (125 khz)
Table of Contents

Advertisement

IPT-HH20
Software description PF_Ident
Instructions on Write fixcode function
Write fixcode
Write a fixcode to a data carrier as follows:
1.
Select Read/Write > Write fixcode > Fix type.
2.
Press the CLEAR input key (
3.
Depending on whether you wish to set a variable or rewritable fixcode, enter the relevant
value using the input keys. See see "Fix type" on page 58
4.
Press the left softkey (
5.
Select Data.
6.
Enter the relevant data in the correct syntax for the data format selected using the input
keys. The length of the fixcode is 5 bytes.
7.
Press the left softkey (
If the character entered does not correspond with the syntax of the data format, a fault
indication is issued and the value is not accepted.
8.
Position the read/write head on the Handheld directly beside the data carrier.
9.
Press the left softkey (
If the write process is successful, "OK" appears on the display and the status LED flashes
green. If you have activated the buzzer and the vibration alarm in the Settings menu, an
acoustic signal sounds and the Handheld vibrates. If the transfer was unsuccessful, the status
LED briefly flashes red and a fault indication is issued. See see chapter 8
Note!
Observe the input format
Data bytes in hexadecimal data format must always contain 2 characters and data bytes in
decimal data format must contain 3 characters.
) to delete the default value.
) to confirm your entry.
) to confirm the entry.
) to confirm the entry.