Set up

8.6.2 "Auxiliary frequency" function settings (AUX menu)

8.6.3 "Flow" function settings (FLOW menu)

8.7 Setting the code (CODE menu)

36
'UNIT' select the units ( 'L' or 'gal' ) using the
10.
Under menu option
arrow keys and press the
ð The pump is calibrated.
Consequence:
The corresponding continuous displays indicate the calibrated values.
n
Total number of strokes and total litres are set to "0" by calibrate.
n
The pump is in the STOP state.
n
Continuous
display
Fig. 27
The programmable function "Auxiliary frequency" facilitates the activating
of an auxiliary stroke rate, which can be set in the
activated via the "External control" terminal. If the auxiliary frequency is
being used, then the identifier
This auxiliary frequency has priority over the stroke rate, which is specified
by the currently selected operating mode.
Continuous
display
Fig. 28
'FLOW' menu only appears if a dosing monitor is connected to the
The
"Dosing monitor" terminal. The metering monitor records the individual
metering strokes of the pump at the pressure connector and reports them
back to the pump control. If this feedback is sequentially missing for as
often as set in the
'FLOW' menu (after a fault or too low metering), the
pump is stopped.
'CODE' menu, you can enter whether you want to block parts of the
In the
adjustment options.
Continuous
display
Fig. 29
[P] key.
'AUX' menu. It can be
'Aux' appears in the LCD screen.