Operation manualⅠ
<Step 6> Check the shape reference position and perform a teaching operation
(adjustment of the position).
After you change the stopper position in <Step 2>, you have to adjust the "shape
reference position."
① Load a board. (See <Step 5>.)
② Display the "Shape clamp position" setting screen.
Select the <Shape Clamp Pos.> button.
③
Use the HOD to check and teach the "X (stopper pin)" position.
<HOD>
* Refer to Section 4.5.2 "Teaching" of the "Instruction Manual CD" for details of how to teach.
WARNING
1. Press the <CAMERA> key.
Board
3. After adjusting the position, press the
<ENTER> key. The value you
entered takes effect.
To avoid risk of injury, do not put your hand, face or head inside the
machine or move any of them close to the machine.
2− 11
Align the cursor to the "X (Stopper
Pin)" field on the screen.
* X stopper pin = Stopper
2. While checking the
teaching monitor, use the
<◄- θ-X> key and/or the
<+θ + ►> key to adjust the
line at which the board and
the stopper are in contact
Stopper
with one another so that
this line can be located in
the center of the monitor in
X direction.