Exiting Programming Mode

To exit the programming mode, press [N] in response to the "REVIEW?" prompt. Then press
[Y] to the "Exit Prog Mode?" prompt. Upon exiting, the root file is updated to log the changes
made. A message is displayed telling the user that this step is being executed. When
complete, the message "DONE" is displayed to indicate the file was successfully uploaded.
If critical configuration changes were made, such as the mode of operation, the IGSMHS will
reset to ensure that the programming features are enabled.
If the file is not successfully uploaded, one of the following prompts will be displayed. Follow
the steps shown below until the upload is successful.
Display
Cannot Upload
Try Again? Y/N_
Failed to Update
Root File!
3-20
4204/
ZONE
ENTRY
TRIG.
2-4204
Description
IGSMHS module is not yet
initialized.
Network problem, or you
answered "N" to "Cannot Upload
Try Again?" prompt.
OPTIONS
Press the [space] key to toggle between the
 Present
options. Press [ENTER] to select the
 Auto
configuration.
Detect
If "Present" is chosen, it is assumed that an IP
is connected to the device. If it is not detected,
a Primary Comm Path Failure message will be
delivered after the programmed fault time
expires.
If "Auto Detect" is chosen, the device will
always try to use IP to communicate but it will
not generate a Primary Comm Path Failure
unless it previously detected the presence of IP.
As soon as the presence of IP is detected, a
Primary Comm Path Restore message is
generated and the value of IP Connectivity pro-
gramming parameter is changed from "Auto
Detect" to "Detected".
From this point on, the software expects
connectivity. The auto detect logic will resume
only when the parameter is changed back to
"Auto Detect".
[Y] =
Reviewing Programming Mode Entries
review
To review the programming options (to ensure
that the correct entries have been made), press
[N] = exit
[Y]. The programming prompts are displayed
again. Use the up/down arrow keys to scroll
through the program fields without changing
any of the values. If a value requires change,
simply type in the correct value. When the last
field is displayed, the "REVIEW?" prompt again
appears.
To exit the programming mode, press [N] in
response to the "REVIEW?" prompt, and refer
to Exiting Programming Mode below.
What to do
Wait for RSSI LEDs to be lit.
Press [Y].
Initiate the Force Server Update
Command by pressing the [0] key; refer
to Section 5: Programmer Keyboard
Commands.
DESCRIPTION