Wiring the IGSMHS

Installation must be in accordance with; the National Electrical Code, UL681 Installation and
UL
Classification for Burglary and Hold-Up Alarm Systems, and UL827 for Central-Station Alarm
Services.
IGSMHS must be connected to a UL Listed dry contact or voltage trigger outputs of a UL Listed
compatible control panel.
All interconnecting wires between the UL Listed control panel and the IGSMHS must be less than 3
feet in length contained in the same room. All interconnecting wiring must be installed in rigid or EMT
(where exposed on interior walls) or in flexible metal tubing if run in the walls or ceiling.
A UL listed control panel must monitor the radio fault output of the IGSMHS. Premises openings and
closings should be sent via the UL listed control panel.
Only ECP mode has been evaluated by UL.
4204 Mode and Two-4204 Mode has not been evaluated.

Wiring a Telco Line Fault Monitor for Zone Mode

When using an Ademco No. 659EN Line Fault Monitor, follow the diagram below for wiring
information. (For detailed information, refer to the Ademco No. 659EN Installation
Instructions P3516-1V2.)
CONTROL PANEL
The Telco line fault monitor should utilize either zone 6 or zone 7 on the IGSMHS. When
programming the IGSMHS ensure the following programming is accomplished. The example
below is for Zone 6.
Programming Prompt
Enable Zn6
Zn6 Trigger Type
Invert Zn6
Restore Zn6
Delay Zn6
Rpt Zn6 ONLY if Armed
No. 659EN Line Fault Monitor
RED
AUX
BLK
POWER
6-14VDC
STAND BY: 5mA
ACTIVE: 35mA
1
2
3
4
5
6
7
8
Setting
[Y]
[V+]
[Y]
[Y]
[00]
[N]
Section 2: Mounting and Wiring
High Security
Communicator
TO TELCO LINE
TB1
(Disregard Polarity)
GND
4
ZONE 6
9
OR
ZONE 7
10
2-3