Honeywell AlarmNet IGSMHS Installation And Setup Manual page 30

Internet communication module
Table of Contents

Advertisement

IGSMHS Installation and Setup Guide
PROMPTS
Exit Prog. Mode?
8
Y/N_
Comm Path
9
Choice
(IP&GSM)_
Device Mode
10
(ECP)_
Important Information Regarding Primary Account (Prompts 11-13)
Account information is provided by the central station administrator.
Primary City ID
11
(??)_
12
Primary CS ID
(??)
13
Primary Sub ID
(????)
Device Address
14
(12)_
3-12
4204/
ZONE
ENTRY
TRIG.
2-4204
OPTIONS
Otherwise, the "Exit Prog. Mode?" prompt is
displayed directly.
[Y], [N]
Exits program mode.
Press [N] to go back to Prompt 3.
[ESC]
Press [ESC] to load factory defaults.
Refer to the Exiting Programming Mode
paragraph in this section.
 IP&GSM
Press the [space] key to scroll through the
communication path choices. Press [ENTER] to
 IP
select.
 GSM
For maximum reliability, select IP&GSM, and
ensure the Internet is connected using the
Ethernet cable.
NOTE: After going from a "GSM" only com
path choice to an "IP" only choice, Prompt 68:
"DHCP" will default to No.
 ECP
Press the [space] key to scroll through the
modes of operation.
 Zone
Trig.
Press [ENTER] to select mode.
 4204
See Table 3-2 for ECP mode programming.
Emu
 Two
4204s
[01-99]
Enter the 2-digit primary city ID, 01-99
(decimal).
[01-FE]
Enter the 2-digit primary central station ID
number, 01-FE (HEX).
[0001-
Enter the 4-digit subscriber account number,
9999]
0001-9999 (decimal).
[01-15]
The IGSMHS communicates with the control
panel as a 4204 relay module. Enter the
appropriate address. For VISTA-10P, and
FA130CP Series control panels, this must be
address 12. For other controls, see the control
panel's Installation and Setup Guide.
NOTES:
1. The 4204 protocol limits address range to
01-15. If using 2-4204 mode, the IGSMHS
assigns the second 4204 to the next higher
device address (e.g., if entering address 12
for the first 4204, then address 13 is
automatically assigned to the second 4204
module). Program the control panel
accordingly.
2. The device address(es) must be unique from
the "Keypad Address" entered in Prompt 16
and any other address used on the control
panel.
DESCRIPTION

Advertisement

Table of Contents
loading