Download Print this page

Honeywell AlarmNet IGSMHS Installation And Setup Manual page 35

Internet communication module
Hide thumbs

Advertisement

Table of Contents
PROMPTS
Restore Zn2 Y/N
36
(Y)_
Delay Zn2 (secs)
37
(00)_
Rpt Zn2 ONLY if
38
Armed (N)_
If Lynx Panic is enabled, then skip to Prompt 43: "Rpt Zn3 ONLY if Armed."
Zn3 Trigger Type
39
(V+)_
Invert Zn3 Y/N
40
(N)_
Restore Zn3 Y/N
41
(Y)_
Delay Zn3 (secs)
42
(00)
Rpt Zn3 ONLY if
43
Armed (N)_
44
Zn4 Trigger Type
(V+)_
45
Invert Zn4 Y/N
(N)_
46
Restore Zn4 Y/N
(Y)_
Delay Zn4 (secs)
47
(00)
Rpt Zn4 ONLY if
48
Armed (N)_
4204/
ZONE
ENTRY
TRIG.
2-4204
2-
4204
only
Section 3: Programming the IGSMHS
OPTIONS
[Y], [N]
Enables restore reporting for zone 2.
UL: Must be set to "Y."
[01-15]
Defines the reporting delay in seconds for
zone 2.
[00] = no
UL: Must be set to 00.
delay
[Y], [N]
Reports alarms on zone 2 ONLY if the
conditional zone (zone 7 in zone trigger mode;
zone 4 in 4204 mode; zone 8 in 2-4204 mode) is
triggered (armed).
If [N], always reports alarms on zone 2.
 (EOLR)
Selects the triggering method for this zone
 (V+)
input. Press the [space] key to scroll through
choices.
 (V–)
UL: V+ must be set as inverted and V– as
non-inverted.
[Y], [N]
Inverts the alarm and normal states of the zone
3 trigger; otherwise uses normal input signal.
[Y], [N]
Enables restore reporting for zone 3.
UL: Must be set to "Y."
[01-15]
Defines the reporting delay in seconds for
zone 3.
[00] = no
UL: Must be set to 00.
delay
[Y], [N]
Reports alarms on zone 3 ONLY if the
conditional zone (zone 7 in zone trigger mode;
zone 4 in 4204 mode; zone 8 in 2-4204 mode) is
triggered (armed).
If [N], always reports alarms on zone 3.
4204 mode: If any zone is programmed to
"Report Only if Armed," skip to Prompt 54:
"Enable Zn6."
 (EOLR)
Selects the triggering method for this zone
input. Press the [space] key to scroll through
 (V+)
choices.
 (V–)
UL: V+ must be set as inverted and V– as
non-inverted.
[Y], [N]
Inverts the alarm and normal states of the zone
4 trigger; otherwise uses normal input signal.
[Y], [N]
Enables restore reporting for zone 4.
UL: Must be set to "Y."
[01-15]
Defines the reporting delay in seconds for
zone 4.
[00] = no
UL: Must be set to 00.
delay
Reports alarms on zone 4 ONLY if the
[Y], [N]
conditional zone (zone 7 in zone trigger mode;
zone 8 in 2-4204 mode) is triggered (armed).
If [N], always reports alarms on zone 4.
DESCRIPTION
3-17

Advertisement

Table of Contents
loading