ADJ MDF2-9SYS User Manual page 21

Hide thumbs Also See for MDF2-9SYS:
Table of Contents

Advertisement

S Y S T E M M E N U
DMX   Mode:   Operating through a DMX controller gives the user the freedom to create their own
programs tailored to their own individual needs. See page 19 for each mode's DMX traits.
DMX Addressing and Channel Mode: This function will allow you to control each individual
fixture's traits with a standard DMX 512 controller.
1.   T o run your fixture in DMX mode, press the MENU button until "Addr" is displayed. Press ENTER
to show the current DMX address, displayed as "AXXX," where "XXX" is the current address.
2.   Use the UP or DOWN buttons to select your desired DMX address, then press the ENTER.
3.   Press MENU until "Addr" is displayed, indicating that you have returned to the main menu
selection.
4.   Use the UP and DOWN buttons to scroll to "NodE". Press ENTER to enter Channel Mode
selection.
5.   Use the UP or DOWN button to scroll to your desired DMX Channel Mode (CH03, CH05, CH07
and Ch10), and press the ENTER button to select.
No DMX Setup: This  mode  allows  the  unit  to  default  to  one  of  four  modes  if  the  DMX  signal  is  lost  
or  interrupted.    
1.  To select your NO DMX Mode, press the MENU button until "nodn" is displayed. Press ENTER to
configure the No DMX Mode setup.
2.  Press the UP or DOWN button to select one of the four options, then press ENTER to select
the desired
mode.  
•  
BLACKOUT = "blAc".
•  
INTERNAL = "Intr".
•  
SETTING = "Sett".
•  
HOLD = "Hold".
Master/Slave Mode: This mode allows one panel to control one or more other panels in the system.
1.   Press the MENU button until "NASt" or "SLAu" is displayed. Press the ENTER button to select
the Master/Slave Mode setting.
2.  
T o run your fixture in Master mode, press the UP or DOWN button until
press the ENTER button to select Master mode.
"Master" unit. All other panels in the system must be set as "Slave" units.
T o run your fixture in Slave mode, press the UP or DOWN button until
3.  
press the ENTER button to select Slave mode.
"Master" unit.
Note: (If using multiple slave fixtures, be sure to set additional fixtures to Slave Mode as well.)
The unit will switch all LED's off if signal is lost.
The unit will default to internal programs when the signal is lost.
The unit will go to manual settings when the signal was lost.
The unit will maintain the same settings as before the signal was lost.
Please note that only one panel can be set as the
The "Slave" unit(s) should now start following the
21
"NASt" is
displayed, then
"SLAu" is
displayed, then

Advertisement

Table of Contents
loading

Table of Contents