Replacing equipment
553-3001-520 Standard 17.00 January 2002
Keycode diskette
Database diskette(s)
one NT5D61AA IODU/C card
one IODU/C Security Device
a Database Transfer Utility to archive the IOP/CMDU or CMDU
database on 2MB floppy diskettes.
Performing a data dump
Before starting this procedure, make a backup copy of the customer database
on a 4MB diskette using the data dump routine:
1
Log into the system
2
Load the Equipment Data Dump Program (LD 43). At the prompt, enter
LD 43
3
When "EDD000" appears on the terminal, enter
EDD
4
When "DATADUMP COMPLETE" and "DATABASE BACKUP
COMPLETE" appear on the terminal, enter
****
CAUTION
Service Interruption
If the data dump is not successful, do not continue;
contact your technical support organization. A data
dump problem must be corrected before proceeding.
To access the Core during the replacement procedure, connect a terminal to
the J25 port on the I/O panel in the Core/Network Module. To communicate
with the processor, you must use the following settings on the terminal:
9600 baud, 7 data, space parity, 1 stop bit, full duplex, XOFF
to load the program
to begin the data dump
to exit the program