Nt5D61 Input/Output Disk Unit With Cd-Rom (Iodu/C); Performing A Data Dump - Nortel Meridian 1 Hardware Replacement Manual

Table of Contents

Advertisement

Page 102 of 250

NT5D61 Input/Output Disk Unit with CD-ROM (IODU/C)

Performing a data dump

553-3001-520 Standard 17.00 January 2002
Replacing equipment
Use this procedure to replace a faulty IODU/C card with a new IODU/C card.
CAUTION
Service Interruption
Performing this procedure in a nonredundant
system, such as 51C, will disrupt system operation.
If possible, schedule the replacement at the lowest
traffic time.
See Administration (553-3001-311) for a description of all maintenance
commands, and System Messages Guide (553-3001-411) for interpreting
system messages.
DANGER
Module covers are not hinged; do not let go of the
cover. Lift the cover away from the module and set it
out of your work area.
CAUTION
Service Interruption
At some point in this procedure the system will
warm start, causing a momentary interruption in call
processing.
Before starting this procedure, make a backup copy of the customer database
on a 4MB diskette using the data dump routine:
1
Log into the system
2
Load the Equipment Data Dump Program (LD 43). At the prompt, enter
LD 43
3
When "EDD000" appears on the terminal, enter
EDD
to load the program
to begin the data dump