Replacing equipment
f.
Clip all cable ties that secure the thermostat harness. Be careful
not to damage other wiring (such as the air probe harness).
g.
Pull the LED through the rubber grommet at the front of the
perforated panel.
h.
Remove the screws (two each) that secure the thermostats.
Remove the thermostats and wiring (see Figure 19 on page 180).
Figure 19
Thermostat harness
Thermostat
wiring
Grommet
Installing equipment
1
Install the replacement thermostat harness:
a.
Position the replacement thermostats and install the screws.
b.
Push the LED through the rubber grommet.
c.
Route the thermostat wiring on the perforated panel. At the rear
edge of the panel, route the wires with wiring for the air probe
harness. Secure loose wiring to the perforated panel with cable
ties.
2
Turn the perforated panel over. Slide it slightly to the right (at the rear
of the column) so it is in a secure position. Position wiring from the
perforated panel so it rests in the cable well next to the orange
connector at the rear of the module (see Figure 20 on page 181).
Position the perforated panel and install the screw that secures it at the
LED mounting bracket.
a.
Slide the LED ring over the LED (see Figure 21 on page 181). The
ring will hang loosely at this point.
To connector J2
Thermostats
Front
LED
Perforated
panel
(bottom)