553-3001-520 Standard 17.00 January 2002
Replacing equipment
Figure 13
Field wiring terminals in the NT7D67CB PDU
NT7D67CB
BLO CB0 CB1
11
Remove the PDU:
Note: When a system is shipped, a set of screws secures the leveling
bracket at the rear of the PDU to protect against vibration during
transit. If the shipping screws were not removed during initial
installation, you must remove them now to pull the PDU out of the
pedestal. Pull the blower unit all the way out of the pedestal so you can
access the shipping screws on the leveling bracket.
a.
Loosen the three screws that secure the PDU.
b.
Remove the two vertical screws located in the rear of the PDU that
hold the L-bracket to the lower pedestal.
c.
Pull the PDU out of the pedestal, being careful to not chafe the
cables against the pedestal.
d.
Disconnect the frame ground wire from the PDU at the frame
ground bolt inside the pedestal.
Installing equipment
1
Install the replacement PDU:
a.
Connect the frame ground wire from the PDU to the frame ground
bolt inside the pedestal.
b.
Guide the connector for the power cable through the hole in the
top of the pedestal (do not allow the PDU to drop).
BAT
BAT
BATRTN
BATRTN
LRTN
0,1
2,3
0,1
2,3
FLTR / PWR DIST
UNIT ASSY
CB2
CB3
553-5800