Ccni To 3Pe Termination Panel Cable Connections; Connect The 3Pe Cables To The 3Pe Termination Panels - Nortel Meridian 1 Hardware Replacement Manual

Table of Contents

Advertisement

Table 3 on page 199 specifies the default Network group assignments for
each cCNI slot and port. These designations can be changed in software if
necessary.
Table 3
cCNI Network group designations
cCNI card
slot
c9
c9
c10
c10
c11
c11
c12
c12

cCNI to 3PE Termination Panel cable connections

The cCNI slot and port connections are labeled on the 3PE Termination
Panel. See Figure 36 on page 200. Each 3PE card is connected with two
cables: one to J3 and one to J4. Table 3 on page 199 specifies the Network
group that connects to each slot.

Connect the 3PE cables to the 3PE Termination Panels

Two NT8D76 cables connect from J3 and J4 of each 3PE faceplate to the 3PE
Termination Panel. See Figure 37 on page 202.
Refer to Table 3 on page 199 for cCNI port and slot assignments. Connect
shelf 0 3PE cards to the Core/Net 0 panel; connect shelf 1 3PE cards to the
Core/Net 1 panel. The 3PE cables for Network group 0 are factory installed.
Replacing equipment
cCNI card
3PE Termination Panel
port
0
N/A (factory installed directly
to the Core/Net backplane)
1
0
1
0
1
0
1
label
Port 9-1
Port 10-0
Port 10-1
Port 11-0
Port 11-1
Port 12-0
Port 12-1
Hardware Replacement
Page 199 of 250
Connected
to Network
group
0
1
2
3
4
5
6
7