Response of the LEDs in operation
LED
Color
RDY
(READY)
Green
Red
Red/
green
Orange
Green/
Orange
or
Red/
Orange
PN
PROFIdrive
cyclic opera‐
tion
Green
Red
Software and hardware
Service Manual, 08/2018, 6FC5397-5DP40-6BA1
State
Description, cause
OFF
Electronics power supply is missing or outside per‐
missible tolerance range.
Continu‐
The component is ready for operation and cyclic
ous light
DRIVE-CLiQ communication is taking place.
Flashing
Commissioning/reset
light
0.5 Hz
Flashing
Writing to the memory card
light
2 Hz
Flashing
General error
light
2 Hz
Flashing
Control Unit is ready for operation.
light
However, there are no software licenses.
0.5 Hz
Flashing
Updating the firmware of the connected DRIVE-
light
CLiQ components
0.5 Hz
Flashing
DRIVE-CLiQ component firmware update com‐
light
plete. Wait for POWER ON for the components in
2 Hz
question.
Flashing
Component detection via LED is activated
light
(p0124[0]).
2 Hz
Note:
Both options depend on the LED status when com‐
ponent recognition is activated via p0124[0] = 1.
Off
Cyclic communication has not (yet) taken place.
Note:
PROFIdrive is ready for communication when the
Control Unit is ready (see LED RDY).
Continu‐
Cyclic communication is taking place.
ous light
Flashing
Full cyclic communication is not yet taking place.
light
Possible causes:
0.5 Hz
● The controller is not transferring any setpoints.
● During isochronous operation, no global control
(GC) or a faulty global control (GC) is
transferred by the controller.
● "Shared Device" is selected (p8929=2) and only
one controller connected.
Flashing
Bus fault,
light
incorrect parameter assignment/configuration.
0.5 Hz
Flashing
Cyclic bus communication has been interrupted or
light
could not be established.
2 Hz
Service cases - hardware
4.9 Control Unit CU320-2 PN and CU310-2 PN
Remedy
Check power supply
Check parameterization/con‐
figuration
Obtain licenses
Perform a POWER ON of the
affected component
Adapt configuration between
controller and devices
Correct the fault