Removing
Ground terminal
X30
Feedrate override
X31
Spindle override
X20
Port 1: Connection: PLC I/O interface based on PROFINET
X21
Port 2: Connection: PLC I/O interface based on PROFINET
Slot for Emergency Stop
Mounting slots for additional command devices
Customer-specific inputs and outputs
Cover plate
Ethernet cable strain relief
LED
S2
Switch for setting the MCP address
S1
Switch for setting the handwheel signal type
X60
Handwheel connection
X61
Reserved
X10
Power supply interface
Figure 4-11
MCP 483C PN rear side
Procedure:
1. Switch-off the control: Completely switch off the system. Check that the system is in a no-
voltage condition and is locked-out so that it cannot be switched on again without the
appropriate authorization.
2. Access the operator panel/control cabinet in which the machine control panel is located.
3. Using a multimeter, check the X10 power supply to ensure that the system really is in a no-
voltage condition.
Software and hardware
Service Manual, 08/2018, 6FC5397-5DP40-6BA1
Service cases - hardware
4.5 Machine control panels
101