This Is How You Remove An Tm54F - Siemens SINUMERIK 828D Series Software And Hardware Service Manual

Hide thumbs Also See for SINUMERIK 828D Series:
Table of Contents

Advertisement

4.18.3

This is how you remove an TM54F

Overview
The activities that must be taken into account when replacing an TM54F are described below.
If a TM54F has a hardware defect, then it must be replaced by an identical module.
Preconditions:
● The module is defective and must be replaced.
● The control cabinet is in a no-voltage condition, all of the connectors and cables are labeled.
Removing
Figure 4-63
Procedure:
1. Label connectors X514 and X524 for the sensor and electronics power supply prior to
withdrawing them.
2. Withdraw the connected DRIVE-CLiQ cables X500 and X501 and write the slot designation
on the cable.
3. Label the connected connectors X520 - X535 for digital inputs and outputs prior to
withdrawing them.
4. Release the protective conductor connection and write the position designation on the
cable.
Software and hardware
Service Manual, 08/2018, 6FC5397-5DP40-6BA1
TM54F removal
Service cases - hardware